2.4 HD6 RUGGED DOME HOUSING , CONTINUED
9. If the heater/blower option or blower option is installed, route the 24Vac wiring
through the conduit fitting and connect at terminal strip TB4 on the heater/blower
board. See
a. Loosen the screw on the terminal strip.
b. Strip the insulation on the wire back approximately 7/16".
c. Insert the wire fully in the hole on the terminal strip to ensure a good contact and
d. Tighten the screw on the terminal strip to secure the wire.
Heater/Blower Option
Power Terminal Strip
TB4-1
TB4-2

Figure 8: Heater/Blower Option

10. Connect the video coaxial cable to the BNC connector in the housing .
The installer must supply the mating BNC connector.
NOTE: If the Unshielded Twisted Pair (UTP) option is installed, the BNC connector
is not used.
11. Feed the excess cabling from the terminal strips and the video cabling back through
the conduit fitting and tighten the cable clamp on the fitting (if applicable).
12. Refer to the HD6 Series User Manual to install the scan.
Rev. 1.02
Figure
8.
to ensure it does not short to adjacent wires.
24VAC POWER
CONNECTIONS
24VAC
24VAC
HEATER/BLOWER POWER REQUIREMENTS
24VAC @ 4A
24 VAC HEATER POWER
MAXIMUM WIRE LENGTHS
AWG
MAX. DISTANCE TO DOME
18
62 FEET (19 METERS)
16
99 FEET (30 METERS)
14
158 FEET (48 METERS)
12
251 FEET (76 METERS)
THERMOSTAT:
ON 70 F
OFF 90 F
OUTPUT 96W
BLOWER ONLY POWER REQUIREMENTS
24VAC @ 0.5A
24 VAC HEATER POWER
MAXIMUM WIRE LENGTHS
AWG
MAX. DISTANCE TO DOME
22
150 FEET (45 METERS)
20
235 FEET (70 METERS)
18
375 FEET (110 METERS)
16
600 FEET (180 METERS)
14
950 FEET (290 METERS)
12
1500 FEET (455 METERS)
14
900.0696
1-Aug-06