2.3

Wiring

(1) For the wiring, strip off the sheath of a cable, and use it with a blade terminal. For a single wire, strip off the sheath of the
wire and apply directly. Insert the blade terminal or the single wire into a socket of the terminal.
Strip off the sheath for the below length. If the length of the sheath peeled is too long, a short circuit may occur with neighboring
wires. If the length is too short, wires might come off.
Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not solder it.
Crimp the blade terminal.
Insert wires to a blade terminal, and check that the wires come out for about 0 to 0.5 mm.
Check the condition of the blade terminal after crimping. Do not use a blade terminal of which the crimping is inappropriate, or
the face is damaged.
Caution
After wiring, wire offcuts must not be left in the inverter. They may cause a fault, failure or malfunction.
Cable sheath stripping length
Damaged
Crumpled tip
Unstranded
wires
Wires are not inserted
into the sleeve