Output Connector; Sync Output Connector; Trigger Key; Output Key - Keithley 3390 User Manual

Arbitrary waveform generator
Hide thumbs Also See for 3390:
Table of Contents

Advertisement

Section 2: Front Panel

Output connector

This connector houses the main signal output. Refer to
settings

Sync output connector

The sync out signal is delivered at this connector. Refer to
for details.

Trigger key

Press the Trigger key to manually generate an immediate trigger that is independent of the trigger
source. This is applicable to sweep, burst, and pattern out operations only.

Output key

Press the Output key to manually enable or disable the generation of waveform signals from the
front-panel output channel. The default setting is OFF. The Output key is lit when enabled.

Help menu key

The Help menu key allows access to the following information:
View remote command error: Error messages are issued when an incorrect remote
command is sent to the instrument for output. These are stored in a queue and can be
retrieved in the first-in-first-out (FIFO) order.
Get HELP on any key: You can view a short description of any front-panel key by pressing
and holding the key for a few seconds.
Generate a DC voltage level: Instructions are provided for you to enable the DC-only
voltage level option.
Generate a modulated waveform: Follow the instructions provided to produce a
modulated waveform.
Default state resetting: Instructions enable you to return the instrument to the factory
default state.
View a waveform in Graph Mode: This information details use of the graph mode.
Synchronize multiple instruments: Follow the detailed instructions for connecting multiple
instruments.
KEITHLEY Technical Support: Keithley Instruments technical support contact information
is located here.

Utility menu key

The Utility menu key allows access to the following settings and parameters:
DC: The DC offset voltage setting can be changed from the Utility menu. The default DC
offset voltage is zero (0) volt for all functions.
Sync: The sync out signal can be turned on and off from the Utility menu. All standard
output functions (with the exception of DC and noise) can be associated with a sync-out
signal. The signal is delivered at the Sync connector on the front panel.
Output Setup: This key contains a number of different parameters. The output termination
setting can be changed, voltage auto ranging can be turned on and off, waveform polarity
can be specified as normal or inverted, the phase offset of the output waveform can be
adjusted, and lastly, the 10 MHz time base output can be turned on and off.
2-4
for details.
Return to
Model 3390 Arbitrary Waveform Generator User's Manual
Section
Section Topics
4,
Editing parameter values and
Section
4,
Front panel connections
3390-900-01 Rev. C / January 2009

Advertisement

Table of Contents
loading

Table of Contents