Overview
JetCon 2401 is a Multi-serial to fiber media converter which has RS-232/RS-422/RS-485
triple mode circuits with auto baud rate and direction control functions. It extends the
distance of serial communication to 5KM (JetCon 2401-m Multi-mode Optical Fiber) or
40KM (JetCon 2401-s Single-mode Optical Fiber) and also provides good immunity of
EMI/EMS. For the ESD protection, JetCon 2401 also passed the 15KV ESD testing on serial
line.
To ensure nonstop transmission in hazardous environment, JetCon 2401 supports wide
o
operating temperature range, -20~70
C model (JetCon 2401) and -40~70
2401-w). Further more, JetCon 2401 supports wide range power input (DC/AC) and DIN
rail mount for quick and easy installation.
Package Check List
JetCon 2401 Industrial serial to fiber media Converter
Quick Installation Guide
DIN rail mount kits
Installation
Mounting the Unit
Din-Rail mount: screw up the DIN rail mount kit with 4 screws and mount JetCon
2401 on the DIN Rail.
Grounding JetCon 2401
There is one earth grounding pole include in power-input
connector. Connect the earth grounding of JetCon 2401
which is within power-input terminal block to ensure
system safety and prevent noise to interfere communication.
Wiring the Power Inputs
1. Insert the positive and negative wires into the V+ and V-
contact on the terminal block connector.
2. Tighten the wire-clamp screws to prevent the power wires
from being loosened.
Accept 24AWG wire.
Notes: The recommended working voltage is DC24V
(DC12~ 48 V) or AC24V (AC 12~32V) with polarity
reverse protection.
Connecting to serial line
The JetCon 2401 provides triple mode circuits for RS-232/RS-422/RS-485 2/4-wires and
extend these signals to 5KM or 40KM by optical fiber cable.The converter operating
architecture can also configure as a PTP (Peer to Peer) or SFR (Serial Fiber Ring) to enlarge
the serial communication infrastructure and link more JetCon 2401. To ensure the quality of
serial line signal, JetCon 2401 provides 2 termination resistors for the RS-422/485 TX and
RX signal by DIP switch enabled/Disable. About the DIP Switch setting, please refer to DIP
Switch setting table.The following information will show the different serial signal
connectivities for your reference.
DTR
JetCon 2401
DSR
RTS
CTS
T+
T-
R+/D+
RX
TX
R-/D-
TX
RX
TX
RX
GND
V+
V-
GND
GND
PC with RS-232 serial
RS-232 serial Mode
DTR
JetCon 2401
DSR
RTS
CTS
T+
T-
o
C model (JetCon
R+/D+
RX
TX
R-/D-
TX
RX
TX
RX
GND
V+
V-
GND
GND
PC with RS-232 serial
RS-232 serial Mode
A Beijer Electronics Group Company
JetCon 2401 Industrial Serial to Fiber Media Converter
JetCon 2401
Quick Installation Guide V1.3
Overview
JetCon 2401 is a Multi-serial to fiber media converter which has RS-232/
RS-422/RS-485 triple mode circuits with auto baud rate and direction control
functions. It extends the distance of serial communication to 5KM (JetCon
2401-m Multi-mode Optical Fiber) or 40KM (JetCon 2401-s Single-mode Optical
Fiber) and also provides good immunity of EMI/EMS. For the ESD protection,
JetCon 2401 also passed the 15KV ESD testing on serial line.
To ensure nonstop transmission in hazardous environment, JetCon 2401
supports wide operating temperature range, -20~70
C model (JetCon 2401) and
o
TX+
RX+
-40~70
C model (JetCon 2401-w). Further more, JetCon 2401 supports wide
o
range power input (DC/AC) and DIN rail mount for quick and easy installation.
T+
Package Check List
Unpack the box, you will find
A Beijer Electronics Group Company
JetCon 2401 is a Multi-serial to fiber media converter which has RS-232/
JetCon 2401 Industrial Serial to Fiber Media Converter
Overview
Quick Installation Guide V1.3
TX-
RX-
T-
JetCon 2401 Industrial serial to fiber
2401 also passed the 15KV ESD testing on serial line.
RS-422/RS-485 triple mode circuits with auto baud rate and direction control
Multi-mode Optical Fiber) or 40KM (JetCon 2401-s Single-mode Optical Fiber)
functions. It extends the distance of serial communication to 5KM (JetCon 2401-m
and also provides good immunity of EMI/EMS. For the ESD protection, JetCon
media Converter
wide operating temperature range, -20~70
To ensure nonstop transmission in hazardous environment, JetCon 2401 supports
input (DC/AC) and DIN rail mount for quick and easy installation.
model (JetCon 2401-w). Further more, JetCon 2401 supports wide range power
o
C model (JetCon 2401) and -40~70
o
C
R+/D+
Quick Installation Guide
JetCon 2401 Industrial serial to fiber
Package Check List
Unpack the box, you will find
Quick Installation Guide
media Converter
DIN rail mount kits
R-/D-
DIN rail mount kits
TX
RX+
TX+
RX
GND
V+
RX-
TX-
V-
GND
GND
PC with 4-wires
RS-422/485 4-wires
RS-422/485
serial Mode
JetCon 2401
T+
T-
R+/D+
Data+
Data+
R-/D-
TX
RX
Data-
Data-
GND
V+
V-
GND
GND
PC with 2-wires RS-485
RS-485 serial Mode
RX
TX
Connecting the Optical Fiber
2401
Serial to Fiber Media Converter
The Fiber Optical link architecture supports PTP and SFR
PWR
TX
RX
Ring
mode for different purposes.
1. PTP Mode (Peer to Peer)
RS-422/485
RS-232
12-48V
The PTP (Peer to Peer) mode provides connection between
Earth Ground
2 nodes. When working on this mode, JetCon 2401 can
transmit data and receive it at same time, which means
JetCon 2401 is working at full duplex mode.
V+ V- GND
2. SFR Mode (Serial Fiber Ring)
To extend the transmission distance and to save
the fiber cable cost, JetCon 2401can link to each
other as a ring architecture, in this mode JetCon
2401 only provides half duplex transmission and
all of data communication is controlled by the
host device. The maximum of communication
nodes can up to 20.
The table below illustrates fiber transceiver specifications
Modul Fiber (um)
JetCon
2401-m
JetCon
2401-S
DTR
JetCon 2401
DSR
TxPwr(Min):Minimum Launch Power
RTS
TX
CTS
RxPwr(Min):Maximum Receive Sensitivity
TX
RX
RX
RX
Link Budget=Minimum Launch Power -Maximum Receive Sensitivity
RX
TX
GND
GND
Note: To ensure your fiber converter transmission/receiving of data between the 2
Fiber
TX
nodes, the attenuation of the optical fiber cable should be smaller than the fiber
RS-232 serial Mode
Device with RS-232 serial
converter's Link Budget.
JetCon 2401
JetCon 2401 DIP Switch Setting
TX
Function
Data+
Data+
RX
RX
RS-422/4 wires (Default)
Data-
Data-
GND
GND
Fiber
TX
RS-485/4 wires
RS-485/2 wires
RS-485/2 wires serial Mode
Device with 2-wires
RS-485 serial
RS-232
JetCon 2401
Function
TX
TX+
RX+
120 Ohm Terminator (RX)
TX-
RX-
RX
120 Ohm Terminator (TX)
RX
RX+
TX+
RX-
TX-
Point to Point /Serial Ring
Fiber
TX
GND
GND
Note: After adjusting the DIP-switch, please reboot the unit to activate the new settings.
RS-422/485 4-wires
Device with 4-wires
serial Mode
RS-422/485 serial
JetCon 2401
Support
TX
5 Years Warranty
Data+
Data+
RX
RX
Data-
Data-
Each of Korenix's product line is designed, produced, and tested with high industrial
GND
GND
Fiber
TX
standard. Korenix warrants that the Product(s) shall be free from defects in materials and
RS-485/2 wires serial Mode
Device with 2-wires
RS-485 serial
workmanship for a period of five (5) years from the date of delivery provided that the
Product was properly installed and used.
This warranty is voided if defects, malfunctions or failures of the warranted Product are
PTP Mode
caused by damage resulting from force measure (such as floods, fire, etc.), other external
forces such as power disturbances, over spec power input, or incorrect cabling; or the
warranted Product is misused, abused, or operated, altered and repaired in an unauthorized
RS232
RS422/485
or improper way.
Attention! To avoid system damage caused by sparks, please DO NOT plug in power
connector when power is on.
The product is in compliance with Directive 2002/95/EC and 2011/65/EU of the European
SFR Mode
Parliament and of the Council of 27 January 2003 on the restriction of the use of certain
Half Duplex
hazardous substances in electrical and electronics equipment(RoHS Directives & RoHS 2.0)
Korenix Customer Service
KoreCARE is Korenix Technology's global service center, where our professional staffs are
JetCon 2401
RS422/485
RS422/485
RS232/422/485
ready to solve your problems at any time Korenix global service center's e-mail is
KoreCARE@korenix.com.
For more information and documents download please visit our website:
http://www.korenix.com/downloads.htm
TXPwr
TxPwr
RxPwr
RxPwr
Connecter Wavelength(um)
LinkBudg(dBm) Distance(km)
(Min)
(Max)
(Min)
(Max)
Multi-mode
ST
820nm
-12dBm -9dBm -28dBm
N/A
16dBm
50~62.5/125
Single-mode
ST
1310nm
-9dBm -8dBm -27dBm
N/A
18dBm
8~10/125
TxPwr(Max):Maximum Launch Power
RxPwr(Max):Minimum Receive Sensitivity
DIP Switch 1
DIP Switch 2
OFF (Default)
OFF (Default)
OFF
OFF
OFF
ON
ON
OFF
DIP Switch
Switch position
Switch 3
Off (Disable)/On (Enable), Default off
Switch 4
Off (Disable)/On (Enable), Default off
Switch 5
Off (PTP)/On (SFR ), Default off (PTP)
5KM
40km
Need help?
Do you have a question about the JetCon 2401-S and is the answer not in the manual?
Questions and answers