■ Setting Function List
Dis-
Setting Function
Symbol
play
<Default Value>
(1)
Counter
: When selected, the counter function
ON/OFF Setting
is available.
: When selected, it is used as a nor-
mal driver.
The display is also OFF.
(2)
Count
The screw fastening count value is set.
Setting Range : 1 to 99
(3)
Count Timer
This function is used to prevent the count
for double tightening operations such as
check fastening or retightening.
Set the operation time while the check fas-
tening is performed for the tightened screw.
Setting Range : 0.00 to 0.99 seconds
Note: When the screw tightening operation
is performed during setting and the
judgment result is normal, the buzzer
sounds once.
(4)
Work Reset Timer
The buzzer sound time period after the
work is completed is set.
Setting Range: 0.0 to 3.9 seconds
Note: Set it based on the reverse count
timer set value.
(5)
Reverse Count
The time period until the reverse count is
Timer
performed is set. Set the work reset timer
operation time based on the time period up
to when the reverse count is performed.
Setting Range: 0.1 to 1.0 seconds
Note: It is available when the "Reverse
Count Enable" has been set in the
system setting.
(6)
System Setting
Each Buzzer or Reverse Count Enable/Dis-
able is set up.
The setting is performed with a combina-
tion of the tens digit and single unit digit.
Tens Digit
0 : Buzzer Enable/Reverse Count En-
able
1 : Buzzer Enable/Reverse Count Dis-
able
2 : Buzzer Disable/Reverse Count En-
able
3 : Buzzer Disable/Reverse Count Dis-
able
Units Digit
2 : Torque Up Buzzer Disable
3 : Torque Up Buzzer Enable
(7)
Over Time /
This sets whether or not the Over Time/
Short Time
Short Time error is detected.
0 : When selected, neither Over Time or
Short Time Error is detected.
1 : When selected, only the Short Time
Error is detected.
2 : When selected, only the Over Time
Error is detected.
3 : When selected, the both Over Time/
Short Time Error are detected.
Dis-
Setting Function
play
<Default Value>
Setting Description
(8)
Accumulated
Counter
■ Operation
Changing to the Setting Mode
Press the F1 switch for more than 2 seconds in the normal mode.
"P" will be displayed in the function display section and the mode will be
changed to the setting mode.
Setting Mode
Each pressing of the F1 switch in the setting mode changes the setting
item. Refer to "Setting Function List" for the setting function details.
Symbol
Setting Description
The accumulated count of the screw fas-
tening operation is displayed.
For the accumulated count, all the torque-
up operations are counted regardless of
whether the counter is ON/OFF.
Display
How to read the display
Units Digit: Numbered in multiples
of 100,000 shots
Tens Digit: Numbered in millions of
shots
(Count)
(Count Timer)
(Work Reset Timer)
(Reverse Count Timer)
(System Setting)
(Over Time/Short Time)
(Accumulated Counter)
Changing to the Normal Mode
Press the F1 switch for more than 2 seconds in the setting mode.
The mode will be changed to the normal mode and the value set for the
count will be displayed.
Counter ON/OFF Setting
Each pressing of the F3 switch toggles ON and OFF.
(Note: F2 button is not to be used.)
Value Setting for Each Function
1. Each pressing of the F2 in the setting mode changes the
fi gure position for setting.
2. Each pressing of the F3 switch increases the value one by one.
Note :The setting procedure is the same for all the settings except
for the "Counter ON/OFF Setting".
Refer to " ■ Setting Function List" for the setting range.