HIOS JUKUREN BLG-BC2 series Operation Manual

Brushless screwdriver with built-in screw counter and pulse system
Hide thumbs Also See for JUKUREN BLG-BC2 series:

Advertisement

Quick Links

Brushless Screwdriver
®
with built-in Screw Counter and Pulse System
"JUKUREN" BLG-BC2 series
Operation Manual
(August 2018)
<Note>
BLG-BC2 I/O Cable set is optional (P/N: BLG-BC2-3010).
Contents
・BLG-BC2 I/O Cable
・Application software (Including the instruction manual)
・Communication specifications
HIOS Inc.
1-16-5 Akiyama, Matsudo City, Chiba Pref., Japan 270-2223
TEL: +81-47-392-2001 FAX: +81-47-392-7778
NO.ET-A011-BC2 18A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JUKUREN BLG-BC2 series and is the answer not in the manual?

Questions and answers

Summary of Contents for HIOS JUKUREN BLG-BC2 series

  • Page 1 Operation Manual (August 2018) <Note> BLG-BC2 I/O Cable set is optional (P/N: BLG-BC2-3010). Contents ・BLG-BC2 I/O Cable ・Application software (Including the instruction manual) ・Communication specifications HIOS Inc. 1-16-5 Akiyama, Matsudo City, Chiba Pref., Japan 270-2223 TEL: +81-47-392-2001 FAX: +81-47-392-7778 NO.ET-A011-BC2 18A...
  • Page 2 Thank you for your purchasing HIOS “JUKUREN” BLG-BC2 Screwdriver. ■ Pulse System The pulse system is a mechanism using an electric signal (pulse) that occurs during motor revolutions. By installing several fasteners into the assembly the driver learns the numbers of motor revolutions required to correctly tighten the fasteners to the desired torque.
  • Page 3 ■ Direct Teaching F1 Button, F2 Button, F3 Button: Control Unit These are used for each setup. Display: No. of motor revolutions is displayed and either Pass/Fail light gets on. ・The No. of motor revolutions is displayed up to triple digits. ・The No.
  • Page 4 Dis- Mode (default) Description Symbol play Counter When selected, the counter function is available. On/OFF OFF: When selected, it is used as a normal driver. Count The screw fastening count value is set. ・ Setting range: 1 to 99 Min. revolutions* The minimum numbers of motor revolutions .
  • Page 5 No Error Time No error time can be set with three bars + values in order to avoid unnecessary for double fastening errors during double fastening. ・This setting is enable only when fastening is done properly. ・Display range: 0.0-9.9 ・Setting range: 0.0-9.9 sec ■...
  • Page 6 Activate screw-counter if necessary. ■ Precautions in the Unit Operation When this unit is used in combination with the existing HIOS external counter, the driver counter does not ● synchronized with the external counter. So, use them based on the external counter function.