(1) Screw Fastening Count Display Section/Set Value Display Section
● I nthenormalmode,thescrewfasteningcountsetvalueis
displayedfirst,andafterstartingthecount,theremaining
screwfasteningcountisdisplayed.
● T hecountdecreaseswitheachscrewfasteningoperation
andtheremainingscrewfasteningcountisdisplayed.
(2) Function Display Section
● T hesymbolcorrespondingtothesetitemisdisplayedinthe
settingmode.
(3) F1 Button
● W henthisbuttonispressedformorethan2secondinthe
normalmode,themodeischangedtothesettingmode.
● T hisbuttonisusedforselectingthefunctioninthesetting
mode.
● W henthisbuttonispressedformorethan2secondinthe
settingmode,thebuzzersoundstwiceandthemodeis
changedtothenormalmode.
(4)F2,F3Button
● U singthesebuttons,thesetvaluecanbechangedinthe
functionsetting.
Somesetvaluesarelimiteddependingonthefunctiontobeset.
(5) Pass Light *
●Whenthescrewfasteningresultis"OK",thegreenLEDlightturnsON.
(6) Fail Light*
●Whenthescrewfasteningresultis"NG",theredLEDlightturnsON.
*
Ifyourunthedriver,thepassofFailOFF.
Other Operations
Thecountistobereturnedto
PressingtheF3Buttonfor2secondsor
thedefaultvalueduringthe
more,resetsthescrewfasteningcount
screwfasteningoperation.
value.
HowtochecktheCounter
Whenthescrewisfastenedforthetime
period(second)setusingthecounter
TimerSetTime.
timer:
● F orcorrectoperation,thebuzzer
soundsonce.
● F orincorrectoperation,thebuzzerdoes
notsound.
Whenthebuzzerdoesnotsound,
increasesthesetvaluegraduallyand
adjustsitsothatthebuzzersounds
once.
Theconfirmationwiththebuzzer
soundisusefulforpreventingascrew
fasteningerror.
LockFButtons.
1.SlidetheFOR/REVswitchtoFOR.
2.Idleforabout20seconds.
→"M"lightisturnedon,andthebuttons
arelocked.
Theywillbeunlockedifyouredothe
abovesteps.
Precautions in the Unit Operation
● W henthisunitisusedincombinationwiththeexistingHIOS
externalcounter,thedrivercounterdoesnotsynchronizedwith
theexternalcounter.So,usethembasedontheexternalcounter
function.
Otherwise,turnoffthedriver'scountingfunctionbeforeuse.
・ C ombinationAvailablewithExternalCounterModelsPowerUnit
BLOP-STC3withtheScrewCounter
SeparateCounterBLOP-SC1
● W hentheoutputsettingforPowerHI/LOWischanged,thedriver
speedchanges.Insuchcases,payattentiontothecountertimer
setvalueandreversecountertimersetvalue.
●Appropriateoperationenvironment.
・ D onotusetheunitinanenvironmentwheretheambient
temperatureisoutsidetherangeof+5to40ºC.
・ I nanareawithstaticelectricity,usethisunitonlyafterremoving
thestaticelectricity.
®
Brushless
Screwdriver
withbuilt-inScrewCounter
BLG-BC1 Series
INSTRUCTIONMANUAL
(July2018)
No.ET-A011-BC118B
Features
●OPC(outputsignals)isavailable.
WhenthedriverisconnectedtotheHIOSrelaybox
"BLOP-AF",anexternaldevicesuchasasequencer,a
revolvinglightorabuzzercanbeusedtovisualizethe
screwfasteningoperationwiththesignals.
T hisunitcanbeusedalsoasanormaldriverwiththe
●
countingfunctioncancelled.ThedisplayisalsoOFF.
T hedriver,runningwithoutfasteningthescrew,orreverse
●
turning,isnotcounted.
S crewfasteningerrorscanbedetectedwitheasyoperation
●
andsetting.
HIOS Inc.
1-16-5Akiyama,MatsudoCity,ChibaPref.,Japan270-2223
TEL:+81-47-392-2001FAX:+81-47-392-7773

Advertisement

loading

Summary of Contents for HIOS BLG-BC1 Series

  • Page 1 Brushless Screwdriver F1 Button Screw Fastening screwfasteningoperation. value. Count Display Section withbuilt-inScrewCounter HowtochecktheCounter Whenthescrewisfastenedforthetime Function Display Section period(second)setusingthecounter TimerSetTime. BLG-BC1 Series timer: ● F orcorrectoperation,thebuzzer soundsonce. ● F orincorrectoperation,thebuzzerdoes INSTRUCTIONMANUAL notsound. (July2018) Whenthebuzzerdoesnotsound, M Light F3 Button No.ET-A011-BC118B increasesthesetvaluegraduallyand Fail Light...
  • Page 2 ■ Setting Function List ChangingtotheNormalMode Dis- Setting Function Symbol Setting Description play <DefaultValue> PresstheF1Buttonformorethan2secondsinthesettingmode. Dis- Setting Function Symbol Setting Description Accumulated Theaccumulatedcountofthescrew play <DefaultValue> Themodewillbechangedtothenormalmodeandthevaluesetfor Counter fasteningoperationisdisplayed. thecountwillbedisplayed. Counter :Whenselected,thecounterfunction Fortheaccumulatedcount,allthetorque- ON/OFFSetting isavailable. upoperationsarecountedregardlessof whetherthecounterisON/OFF. :Whenselected,itisusedasa normaldriver. Display Howtoreadthedisplay ThedisplayisalsoOFF. Count Thescrewfasteningcountvalueisset.