FIGURE 18
In the Configuration panel's Connection control group, the Connection menu group displays optional
sources for inputs. You will see the four local hardware inputs listed first (after Silence) in the menu as
"Input 1", "Input 2", etc.).
Each of the Local connections can be assigned to:
Follow the video source – this is the default setting.
•
A selected embedded audio source (SDI, HDMI or NDI) from among those connected to any
•
Video Switcher input.
Input 2 uniquely provides access to the analog audio inputs on AV-HLC100's backplane, and is
•
available in any Audio Mixer column assigned to Input 2 when the Line option is selected in the
Format menu at right.
Note: Analog audio levels conform to SMPTE RP-155. The maximum input/output level is +24 dBu and
the sample rate is 48 kHz. Analog inputs comprise "line level, balanced" connections.
Returning to the audio Input Configuration panel, note that it holds both basic and advanced audio
features. In the former category, volume sliders are provided below VU meters for each audio source and
32