Invacare® LiNX
4 Troubleshooting
4.1 Error diagnosis
If the electronic system shows a fault, use the following fault-finding
guide to locate the fault.
Ensure that the drive electronics system is switched on
before starting any diagnosis.
If the status display is OFF:
•
Check whether the drive electronics system is SWITCHED ON.
•
Check whether all cables are correctly connected.
•
Ensure that the batteries are not discharged.
If a fault number is displayed in the status display:
•
Proceed to the next section.
4.1.1 Error codes and diagnosis codes
If there is an error with the system when it is powered up, the status
indicator flashes red. The number of flashes indicates the type of
error.
The table below describes the error indication, and a few possible
actions that can be taken to rectify the problem. The actions listed
are not in any particular order and are suggestions only. The
26
intention is that one of the suggestions may help you clear the
problem. If in doubt, contact your provider.
Flash
Error description
code
1
Remote error
2
Network or
configuration error
3
Motor 1
1
error
4
Motor 2
1
error
5
Left magnetic brake
error
Possible action
•
Check cables and
connectors.
•
Contact your provider.
•
Check cables and
connectors.
•
Recharge the batteries.
•
Check charger.
•
Contact your provider.
•
Check cables and
connectors.
•
Contact your provider.
•
Check cables and
connectors.
•
Contact your provider.
•
Check cables and
connectors.
•
Check left magnetic brake is
engaged.
•
Refer to the chapter
"Pushing the mobility device
in freewheel mode" in
the user manual of your
wheelchair.
•
Contact your provider.
1602969-B
Need help?
Do you have a question about the LiNX DLX-REM110 and is the answer not in the manual?
Questions and answers