the COLLATE DJDE in the input file and reconvert the
job.
AIOxxx563W The data stream converter ignored an
incorrect COLLATE change request.
Explanation: The COLLATE DJDE that InfoPrint XT
found is not valid after the first data record of the
report.
System action: InfoPrint XT continues processing the
job.
User response: Make sure of the correct placement of
the COLLATE DJDE in the input file and reconvert the
job.
AIOxxx564E djde_name - DJDE value value is not valid
for the specified conversion units.
|
Explanation: InfoPrint XT cannot process the value
|
value correctly. For units such as IN (inches) or CM
|
(centimeters), InfoPrint XT expects no more than three
|
decimal places. For DOTS, InfoPrint XT expects an
|
integer value.
|
System action: InfoPrint XT continues processing the
|
job, but the output might not be correct.
|
User response: Round any decimal values to three
|
decimal places, or supply integer values for DOTS.
AIOxxx565E djde_name - DJDE value input is not valid
for a numeric entry field.
Explanation: InfoPrint XT cannot process the value
input correctly. InfoPrint XT does not process the DJDE
(djde_name). DJDE naming conventions require a
numeric entry with specific rounding values.
System action: InfoPrint XT continues processing the
job, but the output might not be correct.
User response: Correct the value and reconvert the
job.
AIOxxx566E DJDE_keyword — DJDE option_name is
not valid.
Explanation: The option_name option of the
DJDE_keyword DJDE is not valid.
System action: InfoPrint XT ignores the DJDE
keyword and continues processing.
User response: Correct the DJDE and reconvert the
job.
AIOxxx567E The data stream converter found an
incorrect copy sensitive change request.
Explanation: A copy-sensitive MODIFY, FORMS, or
BFORM change request was made during the
processing of the current report. You can only specify
138
InfoPrint XT Guide
copy-sensitive MODIFY, FORMS, and BFORM
commands at the beginning of a report. The program
ignores the request. After text has printed on a
copy-sensitive report, you can only change a MODIFY,
FORMS, or BFORM command to NONE.
System action: InfoPrint XT continues processing the
job, but the output might not be correct.
User response: Correct the request that was made
after the beginning of the report and reconvert the job.
AIOxxx568E The data stream converter could not
find graphic image resource_name in the
image correlation table and did not
process the command DJDE command.
Explanation: The named resource, resource_name, was
not found. The resource name might be misspelled. The
resource might not be loaded on the InfoPrint XT
server or it might have been loaded as a resource that
belongs to a specific resource group.
System action: InfoPrint XT continues processing the
job, but the output might not be correct.
User response: Check the spelling of the resource
name. Make sure that the resource has been loaded
either as a shared resource or as a resource that belongs
to a specific resource group. Then, reconvert the job.
AIOxxx569E The data stream converter found
incorrect DJDE command command.
Explanation: The listed command (command) is not a
known DJDE command, or its specification or format is
not correct. The program might not process the input.
System action: InfoPrint XT might not continue to
process the job.
User response: Correct the command and reconvert
|
the job. For SHIFT or XSHIFT DJDEs that are not valid,
|
the previous front or back side SHIFT or XSHIFT value
might remain in effect. The DJDE report provides
details.
AIOxxx573W Graphic image image_name is not active.
The data stream converter did not
process the command command.
Explanation: The data stream converter did not find
graphic image image_name before it found the ALTER
or CANCEL command for the image.
System action: InfoPrint XT might not continue to
process the job.
User response: Correct the original Xerox job so that it
uses the syntax rules for graphic images. Then,
reconvert the job.