4. Setup Requirements

The Opener:

a. MUST BE installed in a dry position, protected from weather. (Moisture or corrosion not covered by Warranty)
b. Is factory set for RIGHT HAND SIDE installation (from inside garage), but capable of LEFT HAND SIDE installation.
c. REQUIRES properly earthed 3 pin single phase power within an arms length of door and at a suitable height
d. Requires a MINIMUM SIDEROOM of 41mm from the edge of the door to the inside of the door bracket and 85mm to the
wall.
e. CAN NOT be installed on a Door Axle Diameter that exceeds 35mm.
40mm
85mm
LEFT HAND SIDE

Unsuitable Door Types

The drive must not be used with a door incorporating a wicket
door, unless the drive cannot be operated with the wicket door
open. The fitting of an opener to doors with removable mullions is
not recommended.

Sideroom

The minimum sideroom required from the edge of the door
curtain is 41mm to the inside of the door bracket, and 85mm to
the wall. If a Battery Backup is to be fitted, at least 135mm to the
bracket is required.
Therefore the recommended sideroom from the edge of the door
curtain is 95mm to the inside of the door bracket, and 135mm to
the wall as per diagram.
Controll-A-Door
WARNING!
A portable power generator is
not recommended due to spikes, surges
and fluctuations in the supply.
Power Drive & Roll-A-Pro
®
85
41
Minimum Side room
Recommended Side room
Instruction Manual
5
®
40mm
85mm
RIGHT HAND SIDE
135
95