V3307-DI-T-E2B, WSM
Replacing Fuel Hoses and Clamp Bands
1. Loosen the clamp band (2) and remove the fuel hose (1).
2. Replace new fuel hose (1) and new clamp band (2).
3. Tighten the clamp band (2).
CAUTION
• Stop the engine when attempting the check and change
prescribed above.
(When bleeding fuel system)
1. Fill the tank with fuel and open the cock.
2. Loosen the air vent coupling bolt of fuel filter a few turns.
3. When there is no more air bubbles in the fuel coming out of this
coupling bolt, tighten the coupling bolt.
4. Open the air vent cock (3) on the top of fuel injection pump.
5. If equipped electrical fuel feed pump, turn the key on AC position
and pump the fuel up for 10 to 15 seconds.
If equipped mechanical fuel feed pump, set the stop lever on stop
position and crank the engine for 10 to 15 seconds.
6. Close securely the air vent cock (3) after air bleeding.
IMPORTANT
• Except when venting the air, be sure to keep closed the air
vent coupling bolt of the fuel injection pump. Otherwise, the
engine may stall.
(1) Fuel Hose
(2) Clamp Band
Replacing Intake Air Line
1. Loosen the clamp bands (2).
2. Remove the intake air hose (1) and clamp bands (2).
3. Replace new intake air hose (1) and new clamp bands (2).
4. Tighten the clamp bands (2).
NOTE
• To prevent serious damage to the engine, keep out any dust
inside the intake air line.
(1) Intake Air Hose
Replacing Battery
CAUTION
• When the battery is being activated, hydrogen and oxygen
gases in the battery are extremely explosive. Keep open
sparks and flames away from the battery at all times,
especially when charging the battery.
• When charging battery, remove battery vent plugs.
• When disconnecting the cable from the battery, start with
the negative terminal first. When connecting the cable to the
battery, start with the positive terminal first.
• Never check battery charge by placing a metal object across
the posts.
1. Disconnect the negative terminal and positive terminal.
2. Remove the battery holder.
3. Remove the used battery.
4. Replace the new battery.
5. Tighten the battery holder.
6. Connect the positive terminal.
7. Connect the negative terminal.
G-27
G GENERAL
(3) Air Vent Cock
W1020090
(2) Clamp Band
W1023867
W1023996
KiSC issued 01, 2009 A