DD96
Display Units
Series
Terminal Connection
Connection Diagram
(Name)
(Terminal No.)
Vcc
(A-1)
Power
(B-1)
24V DC
GND
(A-8)
(B-8)
A(2 )
(A-2)
0
(B-2)
B(2 )
1
(A-3)
Data
(B-3)
Input
C(2 )
2
(A-4)
(B-4)
D(2 )
3
(A-5)
(B-5)
Latch
(A-6)
DP
(B-6)
BI
(A-7)
BO
Output
(B-7)
Internal Input Circuit
12 k
Data Input
200 k
GND
A–8, B–8 Terminals
External Wiring
[Contact Input (Digital Switch)]
Vcc (+)
A
D
Power
24V DC
Latch
GND (−)
Note: When connecting a pull-up or pull-down resistor to the external circuit, R1 and R2 should be 2.2 to 10 kΩ (1/2 to 1/4W) and 1 to 2.2 kΩ (1 to 1/2W),
respectively.
Function Table
Data Input
Negative Logic Type
D
C
B
A
Latch
DP
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
H
L
H
H
H
H
H
L
L
H
H
H
L
H
H
H
H
H
L
H
L
H
H
H
L
L
H
H
H
H
L
L
L
H
H
L
H
H
H
H
H
L
H
H
L
H
H
L
H
L
H
H
H
L
H
L
L
H
H
L
L
H
H
H
H
L
L
H
L
H
H
L
L
L
H
H
H
L
L
L
L
H
H
×
×
×
×
L
H
28
Regulating
Circuit
Zero-blanking Circuit
OUT
+12V
[Transistor Input]
R1
Power
Data
24V DC
Input
Tr
When Tr is on,
output goes to L.
LED
Output
Display
Decimal
BO
Display Unit
BI
H
blank
H
L
L
0
L
1
L
2
L
3
L
4
L
5
L
6
7
L
8
L
9
L
blank
L
blank
L
blank
L
blank
L
blank
L
blank
L
maintain
Terminal Arrangement (Connector)
Bottom View
Note: Since power supply terminals and terminals
Applicable Wire: Solid ø0.6 maximum
Vcc (+)
A
Tr
Data
Power
D
Input
24V DC
R2
GND (−)
When Tr is off,
output goes to L.
Input and Output Function
A, B, C, and D (binary code) Input
A, B, C and D are binary-coded decimal inputs corresponding to 1, 2,
4 or 8.
Latch Input
When the Latch input is set to level L, the display at the time is
maintained. (DP and BI inputs are independent.)
DP (Decimal Point)
When the DP input is set to level L, the decimal point turns on.
BI (Zero Blanking Input)
When the BI input is set to level H with 0 displayed, the display is
blanked.
BO (Blanking Output)
The BO output goes to level H during zero blanking. Leading zeros can
be suppressed by connecting the BO to the BI on the lower digits.
Note:
× indicates the display after inputting the Latch signal is maintained regardless of
the voltage level of H or L.
∆ indicates the display is not affected by voltage level of H or L.
DP (decimal point) turns on when the DP input signal is in level L.
B
A
Vcc
(B-1)
(A-1)
Vcc
A(2 )
(B-2)
(A-2)
A(2 )
0
B(2 )
B(2 )
1
(B-3)
(A-3)
C(2 )
C(2 )
2
(B-4)
(A-4)
D(2 )
D(2 )
3
(B-5)
(A-5)
DP
(B-6)
(A-6)
Latch
BO
(B-7)
(A-7)
BI
GND
(B-8)
(A-8)
GND
A(2
0
), B(2
1
), C(2
2
) and D(2
3
) on sides A and
B are internally connected to each other,
connection is sufficient to only one side, but
use terminals on the same side for jumper
wiring.
Stranded AWG28 to 30
Vcc (+)
A
Data
D
Input
GND (−)
0
1
2
3

Advertisement

loading

This manual is also suitable for:

Dd96 seriesDd48 series