Pressure Measurement Of A Tank; Pressure Measurement Of A Liquid In A Pipe - ABB 266FF Operating Instructions Manual

Pressure transmitters 2600t series
Table of Contents

Advertisement

5.13.6 Pressure or absolute pressure measurement of a
tank
— Place the taps in the upper part of the tank.
— Mount the transmitter above the elevation of the process
tap (both pressure and differential pressure transmitter can
be used).
— Connect the transmitter to the tank.
Figure 33: Gauge or absolute pressure measurement on a tank
5.13.7 Pressure or absolute pressure measurement of a
liquid in a pipe
— Place the tap at the side of the line.
— Mount the transmitter (both pressure and differential
pressure transmitters) beside or below the tap for clean
fluids, above the tap for dirty fluids.
— Connect the + (H) side of the transmitter to the pipe.
Figure 34: Gauge or absolute pressure measurement of a liquid in
a pipe
2600T Series Pressure transmitters | OI/266/FF-EN Rev. B 27