Opening The Box; Identification - ABB 266FF Operating Instructions Manual

Pressure transmitters 2600t series
Table of Contents

Advertisement

4. Opening the box

4.1 Identification

The instrument is identified by the data plates shown in Figure 3.
The certification plate (ref. A): contains the certification related
parameters for use in Hazardous area.
The Nameplate (ref.B) provides information concerning the
model code, maximum working pressure, range and span
limits, power supply , output signal, diaphragms material, fill
fluid, range limit, serial number, maximum process working
pressure (PS) and temperature (TS).
Please refer to the serial number when making enquiries to
ABB service department.
The optional additional SST Tag plate (ref. C - code I2) also
provides customer tag number and calibrated range. The
instrument may be used as a pressure accessory (category III)
as defined by the Pressure Equipment Directive 97/23/EC. In
this case, near the CE mark, you will find the number of the
notified body (0474) that have verified the compliance. 266
pressure transmitters are in compliance with
EMC 2004/108/CE*.
The certification plate (ref.A) shown here is issued by ABB
S.p.A, 22016 Lenno, Italy, with the numbers:
FM09ATEX0023X or IECEx FME 09.0002X (Ex d)
FM09ATEX0024X or IECEx FME 09.0003X (Ex ia)
FM09ATEX0025X or IECEx FME 09.0004X (Ex nL)
CE-Identification number of the notified bodies to Pressure
Equipment Directive: 0474, to ATEX certification: 0722, to
IECEx certification: IT/CES/QAR07.0001/02.
ABB S.p.A.
Lenno (Co) Italy
0474
0722
Figure 3: Product identification
*
C and F sensors on gauge and absolute pressure transmitters are in compliance with IEC61000-4-6 with B criteria
10 OI/266/FF-EN Rev. B | 2600T Series Pressure transmitters
ABB S.p.A.
Made in Italy
PRODUCT CODE
SEAL-H
SPEC.REQUEST
SENSOR DIAPH.-FILL
FLANGE/CONN.-GASKET/S
H DIAPH.-FILL
L DIAPH.-FILL
POWER SUPPLY
TS
MWP/OVP
LRL/URL
SPAN LIMITS
Calib.
Range
2600T
Tag
Number
PRESSURE TRANSMITTER
II 1/2 G Ex d IIC T6 - II 1/2 D Ex tD A21 IP67
T85°C FM09ATEX0023X - IECEx FME09.0002X
(-50°C<Ta<+75°C) POWER SUPPLY 42 Vdc/2W Max
II 1 G Ex ia IIC T6 - II 1/2 G Ex ia IIC T6 -
II 1 D Ex iaD 20 T85°C and II 1/2 D Ex iaD 21 T85°C
for electrical parameters see cert. FM09ATEX0024X
IP67 - IECEx FME09.0003X "FISCO Field Instrument"
II 3 G Ex nL IIC T6 - II 3 D Ex tD A22 IP67 T85°C
Ui = 42Vdc Ii < 25mA Ci < 13nF Li < 0,22mH
for electrical parameters see cert. FM09ATEX0025X
IECEx FME09.0004X "FNICO Field Instrument"
The certification plate (ref.A) shown here may also be issued
for ABB-APR, 32425 Minden, Germany, with the numbers:
FM09ATEX0068X or IECEx FME 09.0002X (Ex d)
FM09ATEX0069X or IECEx FME 09.0003X (Ex ia)
FM09ATEX0070X or IECEx FME 09.0004X (Ex nL)
CE-Identification number of the notified bodies to Pressure
Equipment Directive: 0045, to ATEX certification: 0044, to
IECEx certification: DE/TUN/QAR06.0012/01.
The same certification plate (ref.A) can be issued for ABB India
Limited, 560058 Bangalore, India, with the numbers:
FM11ATEX0035X (Ex ia)
FM11ATEX0036X (Ex d)
FM11ATEX0037X (Ex nL)
CE-Identification number of the notified bodies to ATEX
certification: 1725.
ABB Engineering Limited,
issue this certification plate (ref. A), as well. The numbers are:
FM11ATEX0046X or IECEx FMG 11.0019X (Ex ia)
FM11ATEX0047X or IECEx FMG 11.0018X (Ex d)
FM11ATEX0048X or IECEx FMG 11.0020X (Ex nL)
CE-Identification number of the notified bodies to ATEX
certification: 1725.
SERIAL\NUMBER
SEAL-L
HW Rev.
MD:
PED:
OUTPUT SIGNAL
PS
Local keys below label
General Purpose IP67 Max.Supply Voltage 42 Vdc
XP (US) CL I/DIV1/GP ABCD, DIP CL II, III /DIV1/GP EFG,
FM
XP (Canada) CL I/DIV1/GP BCD, DIP CL II, III /DIV1/GP EFG,
US
C
APPROVED
CL I, ZONE 1, AEx/Ex d IIC T4 -50°C<Ta<+85°C
ENCL 4X T AMB=85°C "Seal not required" - "DUAL SEAL"
IS/Sec. Intrinseque (Entity) CL I, ZONE 0 AEx/Ex ia IIC T6,T5,T4
FM
CL I/DIV1/GP ABCD IS - CL II/DIV1/GP EFG - CLIII DIV1 when
US
C
APPROVED
conn. per dwg DH 3173 ENCL 4X "FISCO Field Instrument"-"DUAL SEAL"
CL I, ZONE 2 AEx nC IIC T6,T5,T4
FM
CL I, ZONE 2 Ex nL IIC T6,T5,T4
US
C
CL I/DIV2/GP ABCD NIFW when connected per drawing
APPROVED
DH 3173 ENCL 4X "FNICO Field Instrument" - "DUAL SEAL"
4 Opening the box
Shanghai 201319, P.R. China, can
B
C
A

Advertisement

Table of Contents
loading