Chapter 5
SyncServer S6x0 CLI Command Set
HH=hours.
MM=minutes.
SS=seconds.
mmm=milliseconds.
:=colon separator.
Q=time quality character, as shown below
Example:
To prepare Time on Request, enter:
SyncServer> F9
Then, to request the current time, enter
appear).
Response:
<SOH>128:20:30:04.357*<CR><LF>
To exit
press
F9,
154 SyncServer 600 Series User's Guide
SPACE = Time error is less than time quality flag 1's threshold
. = Time error has exceeded time quality flag 1's threshold
* = Time error has exceeded time quality flag 2's threshold
# = Time error has exceeded time quality flag 3's threshold
? = Time error has exceeded time quality flag 4's threshold, or a
reference source is unavailable
on your keyboard.
Ctrl-C
on your keyboard. ("T" does not
SHIFT-T
098-00720-000 Revision D1 – February, 2018