Honeywell ADEMCO 4110XM Installation Manual page 12

Hide thumbs Also See for ADEMCO 4110XM:
Table of Contents

Advertisement

Installation and Setup Guide
41
6 6 6 6
Primary Phone No.
Enter up to 12 digits
Do not fill unused spaces. To clear entries press *41*.
42
6 6 6 6
Secondary Phone No.
Enter up to 12 digits
Do not fill unused spaces. To clear entries press *42*.
43
6 6 6 6
Subscriber Account No.
Enter 0-9, # + 11 for B; # + 12 for C; # + 13 for D; # + 14
for E; # + 15 for F; Enter * as 4th digit, if 3+1 dialer
reporting will be used.
If only 3 digits are being used, exit by pressing* (and
press 44, if entering next field). To clear entries press
*42*.
44
6 6 6 6
Report Format
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 =or unidentified = 4+2 ADEMCO EXPRESS
7 = ADEMCO Contact ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
Select format for primary/secondary phone numbers.
45
6 6 6 6
Phone System Select
If Central Station IS NOT on a WATS line:
0 = Pulse Dial; 1 = Tone Dial
If Central Station IS on a WATS line:
2 = Pulse Dial; 3 = Tone Dial
Select the type of telephone service
46
6 6 6 6
SESCOA/Radionics Select
0 = Radionics (0-9, B-F reporting); 1 = SESCOA (0-9 only
reporting)
Select 0 for all other formats.
47
6 6 6 6
15 Second Dialer Delay (Burglary)
0 = no; 1 = yes
Provides delay of Burglary report to Central Station.
48
6 6 6 6
Periodic Test Message
0 = none; 1 = 24 hrs; 2 = weekly
(Initial report is sent 12 hrs after exiting programming
or downloading)
49
6 6 6 6
Split/Dual Reporting
To Primary Phone No.
0 = All
1 = Alarms, Restore, Cancel
2 = All Reports Except
Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All Reports Except
Open/Close, Test
5 = All Reports (Dual Reporting
To Primary Phone No.
6 = All Reports Except
Open/Close
7 = All Reports
8 = All Reports
(enter Test Code in field *64)
To Secondary Phone No.
Backup Report Only
Other Reports
Open/Close, Test
All Reports
All Reports
All Reports
To Pager No. †† (secondary)
Alarms, Open/Close, Troubles
Alarms, Troubles
Alarms, Open/Close, Troubles
Entering a number other than the one specified will give
unpredictable results.
†† Can only be used if primary reporting format is ADEMCO Contact ID®.
Used to select a reporting option as follows:
Enter: 0 - 5 when reporting to telephone receivers.
6 - 9 when reporting to a pager is desired.
Touch Tone codes for paging are defined as follows:
1911 = Alarm
1001 = Open
1002 = Close
1811 = Trouble
Note: Restore reports are not sent to the pager.
Programming Report Codes for Alarm System Status,
Restore *50-*74
For 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–
9, 0, B, C, D, E, or F. Enter #+10 for 0 (this reports a 0 on some
receivers), #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15
for F.
For Expanded or 4+2 Format: Enter codes in both boxes (1st and
2nd digits) for 1–9, 0, B–F, as described above.
For ADEMCO Contact ID® Reporting: Enter any digit (other than
"0") in the first box to enable the zone to report. This is an
"enabling" code only and is not the actual code sent to the Central
Station office. Entries in the second boxes are ignored. An entry of
0 in the first box disables the report.
An entry of 0 in the first box disables a report.
Entering 0 in the second box advance to the
next field. An entry of 0 in the second box will
result in automatic advancement to the next field
when programming. To send "0" as a digit you
must enter # +10.
Alarm Report Codes ( 6 6 6 6 50- 6 6 6 6 59)
50
6 6 6 6
1st Digit of Zn95, Zn96 (Keypad Panics)
0 = No Report, 1-9, B-F (as described above).
2nd Digit of each (for expanded 4+2 reporting) is the
same as field *57.
Zone 95 is Console Silent Panic (Key A or 1 & *.)
Zone 96 is Console Audible Panic (Key C or 3 & #).
51
6 6 6 6
Zone 1 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
52
6 6 6 6
Zone 2 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
53
6 6 6 6
Zone 3 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
54
6 6 6 6
Zone 4 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
55
6 6 6 6
Zone 5 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
56
6 6 6 6
Zone 6 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
57
6 6 6 6
Zone 7 Alarm Report Code
0 = No Report, 1-9, B-F (as described above).
Console Panic: Key B or *+#