Input terminal block status (FD06, FE06)
Input terminal block status (current status): "Communication Number FD06"
Input terminal block status (status immediately before the occurrence of a trip): "Communication
Number FE06"
Using terminal function selection parameters, functions can be assigned individually to the terminals
on the input terminal block.
If a terminal function selection parameter is set to 0 (no function assigned), turning on or off the
corresponding terminal does not affect the operation of the inverter, so that you can use the termi-
nal as you choose.
When using a terminal as a monitoring terminal, check beforehand the function assigned to each
terminal.
Data composition of input terminal block status (FD06, FE06)
Bit
0
1
2
3
4
5
6
7
8 to15 (Undefined)
Note: The bit described "Undefined" is unstable. Don't use the bit for the judgment.
*2:S3 function when f147 is logic input.
*2:VIA / VIB function when f109 is logic input.
Example: Data set for FE06 when the F and RES terminals are ON = 0005H
FE06:
FE07:
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Terminal name
F
Input terminal function selection 1 (f111)
R
Input terminal function selection 2 (f112)
RES
Input terminal function selection 2 (f113)
S1
Input terminal function selection 4 (f114)
S2
Input terminal function selection 5 (f115)
S3 *1
Input terminal function selection 6 (f116)
VIB *2
Input terminal function selection 7 (f117)
VIA *2
Input terminal function selection 8 (f118)
---
BIT15
0
0
0
0
0
0
Function (parameter title)
0
0
0
0
0
0
0
0
0
0
57
E6581913
0
OFF
ON
---
bit0
1
0
1
5
1
---

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents