Communication command 2
This command is enabled only when the communication command is enabled. Set Bit 15 of
Communication Command 1 (communication Number: FA00) to "1" (enable). When enabling the
communication command by Communication Command 1, commands by communication can be
given the priority irrespective of the setting of the command mode selection parameter (cm0d).
However, if "48 (49): Forced switching from communication to local is set by input terminal function
selection (f1o4, f108, f110 to f115), the enabled command and frequency will be
given the priority.
Once enabled, this setting will be enabled till disable is set (0 setting), power is turned off or is reset,
or factory default setting (typ) is selected. Electric power quantity reset is always enabled even
though communication command priority is not set.
Table 2 Data construction of communication command 2 (FA20)
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Note: Set 0 to reserved bit
Communication command 3
The RY Terminal Output Hold Command and OUT Terminal Output Hold Commandare alway
s enabled even though communication command priority is not set.
Table 3 Data construction of communication command 3 (FA26)
Bit
0
1
2-15
Note: Set 0 to reserved bit
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
(Communication Number : FA20)
Function
(Reserved)
Electric
power
quantity
reset
(Reserved)
(Reserved)
(Reserved)
(Reserved)
(Reserved)
Maximum
deceleration
forced stop
Acceleration/deceleration
00: Acceleration/deceleration 1
pattern selection 1
01: Acceleration/deceleration 2
10: Acceleration/deceleration 3
Acceleration/deceleration
pattern selection 2
(Reserved)
(Reserved)
OC stall level switch
(Reserved)
(Reserved)
(Reserved)
(Communication number: FA26)
Function
RY terminal output hold
OUT terminal output hold
(Reserved)
0
1
-
-
OFF
Reset
-
-
-
-
-
-
-
-
-
-
Normal
Enabled
-
-
-
-
OC stall 1
OC stall 2
-
-
-
-
-
-
0
1
Once it is turned
on, a RY termi-
OFF
nal holds that
condition.
Once it is turned
on, an OUT ter-
OFF
minal holds that
condition.
-
-
53
E6581913
Remarks
Electric
power
quantity
(FE76, FE77) reset
Select Acceleration/ de-
celeration 1 - 3 by com-
bination of two bits
AD1: , 
AD2: , 
AD3: , 
OC stall 1 : f601
OC stall 2 : f185
Remarks
Always enabled even if
communication command
is not enabled
Always enabled even if
communication command
is not enabled

Hide quick links: