2) Error Processing (Binary mode)
In case an error occurs, communication error command (4EH(N) or 6EH(n)) and the error type
number is returned to the computer in addition to the checksum.
(3.5bytes
Blank)
"N" or "n" (1 byte) : Communication error command. Also for check during an inverter trip (includes standing
DATA (2 bytes)
 Examples
Computer → Inverter : 2F 58 02 05 C4 00 17 70 D8
Inverter → Computer : 2F 4E 00 04 81 ... Checksum error
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Omissible
"/"
INV-NO
Norn
(2FH)
1 byte
(4EH)(6EH)
Checksum area
by for retrying and trip holding). "4EH (N)" is during normal condition, "6EH (n)" is during
trip.
: Error code (0004)
0004
: Checksum error (The checksum does not match)
No return : Command error, format error (specified number of bytes is not received in 1sec,
or parity error, overrun error or framing error), inverter number mismatch, and
inverter number other than 00H in broadcast communication.
DATA
2 bytes
Not omissible
16
E6581913
SUM
(3.5bytes
1 byte
Blank)