Download Print this page

Martin THRILL Compact PAR 64 LED Safety And Installation Manual page 2

Advertisement

Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging
structure. It must be suspended vertically,
hanging downwards only. Use a suitable
rigging clamp such as a super lightweight half-
coupler clamp (shown to right) fastened to the
included clamp attachment bracket.
To clamp the fixture to a truss:
1.
Check that the rigging structure can support at least 10
times the weight of all fixtures and equipment to be installed
on it and complies with locally applicable regulations.
2.
Block access under the work area.
3.
Fold the two parts of the multi-function bracket together.
4.
Bolt a rigging clamp securely to the supplied clamp-
attachment bracket. The bolt used must be M12, grade 8.8
steel minimum, and fastened with a self-locking nut or wing-
nut/self-locking washer combination
5.
Working from a stable platform, hang the fixture vertically
on the truss and fasten the rigging clamp to the truss.
6.
Secure the fixture with a safety cable as directed.
7.
Tilt the fixture as desired and tighten the hand wheels.
Securing with a safety cable
Secure the THRILL Compact PAR 64 LED with
a safety cable or other secondary attachment
that is approved for the weight of the fixture to
prevent it from falling if the primary attachment
fails. Loop the safety cable through the
secondary attachment point on the rear
mounting plate and around a secure anchoring
point.
Do not loop the safety cable around the mounting
bracket only, as this will leave the fixture unsecured
if it separates from the bracket.
AC power
For protection from electric shock, the
fixture must be grounded (earthed). The
power distribution circuit must be equipped
with a fuse or circuit breaker and ground-
fault (earth-fault) protection.
The fixture has an auto-ranging power supply that accepts 100-
240 V AC mains power at 50/60 Hz. Do not apply AC mains
power at any other voltage or frequency. To prevent damage, do
not use an external dimming system to supply power.
If a suitable IEC extension cord is obtained, additional fixtures
may be connected to the MAINS OUT socket, but do not exceed
a current load of 3 A. If supplying power to additional Compact
PAR 64 LED fixtures, you may connect up to:
• Six (6) additional Compact PAR 64 LED fixtures at 100-120 V,
or
• Ten (10) additional Compact PAR 64 LED fixtures at 200-240 V.
Control data link
IN
OUT
IN
OUT
IN
OUT
IN
OUT
DMX Controller
DMX Terminator
The DMX IN socket is for connection to a DMX-512 controller.
The DMX OUT socket may be used to connect a total of up to 32
fixtures in a daisy chain for DMX operation or synchronized
master/slave operation.
Use 3-pin XLR DMX data cable. Microphone cable is designed
for audio signals and is unreliable for data transmission.
Terminate the data link by installing a termination plug in the
output of the last fixture. The termination plug "soaks up" the
control signal so it does not reflect and cause interference.
Maintenance
Do not open the housing, there are no
user serviceable parts inside the fixture.
Disconnect the fixture from mains power
before performing maintenance.
The user may carry out the maintenance operations described
below. Do not attempt to repair a defective fixture. Refer all
service to your Martin dealer or contact Martin directly for
technical support through www.martin.com/contact-support.
Cleaning
The Compact PAR 64 LED must be cleaned periodically.
Excessive dust, effect fluid, and particle buildup degrades
performance, causes overheating and will damage the fixture.
Damage caused by inadequate cleaning is not covered by the
product warranty.
The cleaning schedule will vary greatly depending on the
operating environment. Inspect the fixture once a month and
clean if necessary. Inspect every 1-2 weeks if the fixture is
frequently used with effects machines, in locations with heavy
cigarette smoke, operated or stored in a dusty location, or
installed near an air duct. This procedure will allow you to assess
cleaning requirements in your particular situation.
Keep the fixture dry and use gentle pressure when cleaning.
Work in a clean, well-lit area. Do not use any cleanser that
contains solvents or abrasives, as these can cause surface
damage.
To clean the fixture:
1.
Disconnect the fixture from power and allow it to cool.
2.
Disconnect the fixture from power and allow it to cool.
3.
Clean the casing and lenses by wiping gently with a soft,
clean microfiber cloth. Remove stuck particles with an
unscented tissue or cotton swab moistened with distilled
water. Do not rub hard.
Replacing the primary fuse
Replace fuse with same size and specified rating only.
If the fixture is completely dead, the primary fuse may have blown
and it may be necessary to install a new fuse. A spare fuse is
located in the fuse holder.
Specifications
Physical
Dimensions (LxWxH) ............ 262 x 127 x 266 mm (10.3 x 5 x 10.4 in.)
Maximum standing footprint ....................... 266 x 204 mm (10.4 x 8 in.)
Weight ............................................................................ 2.1 kg (4.3 lbs.)
Dynamic Effects
Color mixing ..........................................................................RGBWAUV
Color selection .............................................................. 36 color presets
Electronic dimming ...................................................................... 0-100%
Strobe and pulse ..................Variable speed and action, random strobe
Electronic 'shutter' effect ................................Instant open and blackout
Control and Programming
Control options ............................. DMX, stand-alone, IR remote control
DMX channels .................................................................................... 6/9
Stand-alone triggers ........................................... Sound-trigger, auto-run
Interface ................................................. Control panel with LED display
DMX compliance .................................. ANSI E1.11 - USITT DMX512-A
Optics
Light source ................................................. 5 x 12 W RGBWAUV LEDs
Minimum LED lifetime ........... 30 000 hours (to >70% luminous output)*
Beam angle ........................................................................................ 18°
*Figure obtained under manufacturer´s test conditions
Construction
Color ............................................................................................... Black
Housing ................................High impact flame retardant thermoplastic
Ingress protection ............................................................................ IP 20
Installation
Mounting .............................. Adjustable bracket, surface or truss mount
Mounting points ................. Bracket for single rigging clamp, M12 or ½"
Orientation ......................................................................................... Any
Location ...................................................................... Dry locations only
Connections
AC power in/thru .................. IEC male inlet/female connector, C14/C13
DMX data in/thru ..................................................................... 3-pin XLR
Electrical
AC power .................................................. 100-240 V nominal, 50/60 Hz
Fuse .................................................................................... F 3AL, 250 V
Total typical power consumption ..................................................... 50 W
Maximum AC Mains Out current ........................................................ 3 A
Typical power and current
110 V, 60 Hz ........................................................................ 50 W, 0.5 A*
230 V, 50 Hz ........................................................................ 50 W, 0.3 A*
*Measurements made at nominal voltage with all LEDs at full intensity.
Allow for a deviation of +/- 10%.
Thermal
Cooling .............................................. Forced air, temperature regulated
Maximum ambient temperature (T
max.) ....................... 40° C (104° F)
a
Minimum ambient temperature (T
min) .............................. 0°C (32° F)
a
Total heat dissipation ......................................................... 170 BTU/hr.*
*Calculated, +/- 10%, at full intensity, full white
Approvals
EU safety .............. EN 60598-1, EN 60598-2-17, EN 62471, EN 62493
EU EMC ............... EN 55015, EN 61000-3-2, EN 61000-3-3, EN 61547
US EMC (pending) .................................. CFR Title 47 Part 15 Class A
Canadian EMC (pending) ........................................... ICES-003 Class A
Australia/NZ (pending) .................................................................... RCM
Included Items
Power cable, EU, IEC C13 female, molded Schuko, 1.5 m (4.9 ft.)
Power cable, US, IEC C13 female, molded NEMA 5-15P, 1.5 m (4.9 ft.)
Multi-function bracket and hardware
IR remote control, grey, 16-button
Battery for remote control, 3 V, CR2025 lithium
Accessories
Super lightweight half-coupler, black ............................... P/N 91602018
Safety cable, SWL 60 kg (132 lb.), BGV C1/ DGUV 17, Black
.......................................................................................... P/N 91604006
Related Items
Martin
®
M-Touch............................................................... P/N 90737040
®
Martin
M-Play .................................................................. P/N 90737030
Ordering Information
THRILL Compact PAR 64 LED ........................................ P/N 90280116
Specifications subject to change without notice. For latest product
specifications, see
www.martin.com
FCC Compliance
This device complies with Part 15, Class B, of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation
Canadian Interference-Causing Equipment Regulations -
Règlement sur le Matériel Brouilleur du Canada
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences
du Règlement sur le Matériel Brouilleur du Canada.
Disposing of this product
®
THRILL by Martin
products are supplied in compliance with
Directive 2012/19/EC of the European Parliament and of the
Council of the European Union on WEEE (Waste Electrical
and Electronic Equipment), where applicable.
Help preserve the environment! Ensure that this product is
recycled at the end of its life. Your supplier can give details
®
of local arrangements for the disposal of THRILL by Martin
products.
Information subject to change without notice. HARMAN
Professional Denmark ApS disclaims liability for any injury,
damage, direct or indirect loss, consequential or economic loss
or any other loss occasioned by the use of, inability to use or
reliance on the information contained in this document.
©2017 HARMAN Professional Denmark ApS. All rights reserved.
®
Martin
is a trademark of HARMAN Professional Denmark ApS
registered in the United States and/or other countries. Features,
specifications, and appearance are subject to change without notice.
HARMAN Professional Denmark ApS
Olof Palmes Allé 18 • 8200 Aarhus N • Denmark
www.martin.com
Document revision: A

Advertisement