Heat & Glo 6000CLX-IFT-S Installation Manual page 23

Hide thumbs Also See for 6000CLX-IFT-S:
Table of Contents

Advertisement

Top Vent - Horizontal Termination
One Elbow
Note: For corner installations: A 6 inch (152
mm) section of straight pipe may need to
be attached to the appliance before a 90º
elbow, to allow the vent pipe to clear the top
standoffs.
V
Minimum
1
Elbow only
1 ft.
2 ft.
3 ft.
4 ft.
5 ft.
V
+ H
1
H
1
Figure 4.9
6000 MODELS
H
Maximum
1
2 ft
610 mm
305 mm
3 ft.
914 mm
610 mm
6 ft.
914 mm
11 ft.
3.4 m
1.2 m
16 ft.
1.5 m
20 ft.
6.1 m
= 40 ft. (12.2 m) Maximum
1
= 20 ft. (6.1 m) Maximum
ELBOW HEAT SHIELD
(Required when V
= 2 ft. or less)
1
Heat & Glo • 6000CLX-IFT, 8000CLX-IFT Installation Manual • 2506-980 Rev. B • 3/18
WARNING! Risk of Fire! Elbow heat shield required
when V
= 2 ft. or less. Clearances to combustibles
1
must be maintained. See Section 5.A.
V
Minimum
1
Elbow only
1 ft.
2 ft.
1.8 m
3 ft.
4 ft.
4.9 m
5 ft.
V
+ H
1
H
H
1
8000 MODELS
H
Maximum
1
1 ft
305 mm
305 mm
3 ft.
914 mm
610 mm
6 ft.
914 mm
11 ft.
3.4 m
1.2 m
16 ft.
1.5 m
20 ft.
6.1 m
= 40 ft. (12.2 m) Maximum
1
= 20 ft. (6.1 m) Maximum
1
V
1
1.8 m
4.9 m
23