Tab. 1/g
LOGIC "CA"
AUTOMATED
OPEN A
SYSTEM STATUS
opens and closes
CLOSED
after the pause
WHEN OPENING
no effect
OPEN IN PAUSE
resets pause time
immediately
WHEN CLOSING
reverses to
opening
opens and closes
BLOCKED
after the pause
Tab. 1/h
MAINTAINED COMMANDS
LOGIC "C"
AUTOMATED
OPEN A
SYSTEM STATUS
CLOSED
WHEN OPENING
no effect
OPEN
(closing inhibited)
immediately
WHEN CLOSING
reverses to
opening
BLOCKED
 In brackets, the effects on the other inputs when the pulse is active
CLOSE
no effect
time
closes
immediately
after opening is
completed
closes
no effect
closes
time
CLOSE
opens
no effect
/
no effect
closes
/
opens
closes
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
resets pause
blocks
time
operation
(closing inhibited)
reverses to
blocks
opening and clo-
ses after pause
operation
time
no effect
no effect
(opening and
(closing inhibited)
closing inhibited)
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
blocks
no effect
operation
blocks
blocks
operation
operation
no effect
no effect
(opening and
(closing inhibited)
closing inhibited)
22
LOOP 1
LOOP 2
opens and closes
after the pause
no effect
time
immediately
no effect
after opening is
completed
closes when
resets pause time
disengaged
immediately
immediately
reverses to
reverses to
opening
opening
opens and closes
no effect
after the pause
(closing inhibited)
time
PULSES
LOOP 1
LOOP 2
no effect
no effect
no effect
no effect
no effect
no effect
(closing inhibited)
(closing inhibited)
blocks
blocks
operation
operation
no effect
no effect
(closing inhibited)
(closing inhibited)
closes