Introductory information
Commissioning
The commissioning and matching of the control unit to
local conditions and building characteristics, as well as
instructing the user in the operation of the system,
must be carried out by your heating contractor.
Your system is preset
Your heating system is preset at the factory and is
therefore ready for operation:
Central heating
Between 06:00 and 22:00 h, the rooms are heated
to 20 °C "Set room temperature" (standard room
temperature).
Between 22:00 and 06:00 h, the rooms are heated
to 3 °C "Reduced room temperature" (reduced
room temperature, frost protection).
DHW heating
Between 05:30 and 22:00 h, the DHW is heated to
50 °C "Set DHW temperature". Any installed DHW
circulation pump is switched on.
Between 22:00 and 05:30 h, the DHW cylinder is not
reheated. Any installed DHW circulation pump is
switched off.
Note
Any DHW heating begun before 22:00 h is termina-
ted.
Energy saving tips
Central heating
Standard room temperature (see page 29):
Do not overheat your home. Every degree of room
temperature reduction saves up to 6 % on your heat-
ing bills.
Never set your standard room temperature ("Set
room temperature") higher than 20 °C.
Time program (see page 16):
Heat your home to the standard room temperature
during the day and the reduced temperature at night.
Set this via the time program.
Operating program:
If you do not require central heating, select one of
the following operating programs:
"Only DHW" (see page 35):
If you require no heating for your home in summer,
but you require DHW.
"Standby mode" (see page 27):
If you don't need to heat your home and don't
require DHW for long periods.
10
As the user of new combustion equipment, you may be
obliged to notify your local flue gas inspector of the
installation [check local regulations]. Your local flue gas
inspector will also inform you [where appropriate]
about work he may be required to carry out on your
combustion equipment (e.g. regular checks, cleaning).
Mechanical ventilation
If a ventilation unit is connected to the Vitotronic:
Operation with "Normal" ventilation level from 00:00
to 24:00 h.
Frost protection
Your boiler and DHW cylinder are protected against
frost.
Wintertime/summertime changeover
This changeover is automatic.
Date and time
The date and time have been set by your heating
contractor.
You can change the settings at any time to suit your
individual requirements.
Power failure
All settings are saved if there is a power failure.
Short absence (see page 32):
Reduce the room temperature if you are going out
shopping, for example. For this, select "Economy
mode".
Holidays (see page 29):
If you are going away, select the "Holiday pro-
gram":
The room temperature is reduced and DHW heating
is turned off.
Ventilation:
Close the thermostatic valves when ventilating/airing
manually. Open the windows fully for a brief time.
Roller shutters:
Close roller shutters (if installed) at dusk.
Thermostatic valves:
Ensure that thermostatic valves are properly adjus-
ted.
Radiators:
Never cover radiators or thermostatic valves.