Technical Specifications
Table A-3
Cisco 819 ISR Specifications (continued)
Description
Altitude
Cable Length
Inrush Current
Temperature
Humidity
Thermal Shock
Vibration
Shock
Martek Railway Power Adapters
Nominal Input Voltages
In-ceiling Plenum
IP 65
Extended Shock-vibe
Maximum Power
Consumption
Maximum Output Power
Rating
Operating Temperature
OL-27407-02
Hardened Design
Specification
(Cisco 819HG and Cisco
819HG-4G ISRs)
Operating: –500 to 10,000 ft, de-rating operating temperature 1°C per 1,000 feet
Non-operating: –1,000 to 30,000 ft
Input cable: 1 m
Output cable: 1.3 m
50 A @ 25°C
Operating: –30 to 60°C, still air condition
Non-operating: –40 to 85°C
Operating: 10% to 95%, non-condensing
Non-operating: 10% to 95%, non-condensing
Operating: –20 to 60°C at 0.5°C per minute
Non-operating: –40 to 85°C with change over time between 2 and 3 minutes.
Operating: 0.41 grms from 3 to 500 Hz with spectral break points of 0.0005 g2/Hz at 10 Hz
and 200 Hz and 5 dB/octave roll off at each end; 2 hours per axis.
Non-Operating: 1.12 grms from 3 to 500 Hz with spectral break points of 0.0065 g2/Hz at 10
Hz and 100 Hz and 5 dB/octave roll off at each end; 30 minutes per axis.
Half sine (operating):
Duration = <2ms
Velocity = 2.11m/s
Number of shocks: a series of 6 shocks one on each side
Trapezoidal shock (non-operating):
Duration = 12 to 25 ms
Number of shocks: a series of 6 shocks one on each side
2
Non-Hardened Design
Specifications
(Cisco 819G and Cisco
819G-4G ISRs)
Cisco Integrated Services Router Hardware Installation Guide
Cisco 810 Series
Hardened Design Specifications
(C819HGW and C819HWD ISRs)
24 V
52 V
72 V
No
Yes
Yes
EN50155 (EN61373) and RIA20
25 W
20 W
–13 to 140°F
(–25 to 60°C)