Troubleshooting - Graco 248171 Instructions Manual

Air-operated diaphragm pumps. d51 series; d52 series; d55 series; d5a series; d5b series; d5e series; d53 series; d54 series; d5c series; d5d series
Hide thumbs Also See for 248171:
Table of Contents

Advertisement

Read Pressure Relief Procedure on page 10, and relieve the pressure before you check or service the
equipment. Check all possible problems and causes before disassembling the pump.
PROBLEM
Pump will not cycle, or cycles once
and stops.
Pump cycles at stall or fails to hold
pressure at stall.
Pump operates erratically.
Air bubbles in fluid.
Fluid in exhaust air.
Pump exhausts air from clamps
(metal pumps).
Pump leaks fluid from check valves.
12 308981

Troubleshooting

CAUSE
Air valve is stuck or dirty.
Leaky check valves or o-rings.
Worn check balls or duckbill valves
or guides.
Check ball wedged in guide.
Worn diaphragm shaft seals.
Clogged suction line.
Sticky or leaking check valve balls.
Diaphragm ruptured.
Suction line is loose.
Diaphragm ruptured.
Loose manifolds or damaged mani-
fold o-rings.
Loose fluid side diaphragm plates.
Diaphragm ruptured.
Loose fluid side diaphragm plates.
Worn diaphragm shaft seals.
Loose clamps.
Air valve o-ring is damaged.
Worn or damaged check valve
o-rings.
CAUSE
Use filtered air.
Replace.
Replace.
Repair or replace.
Replace.
Inspect; clear.
Clean or replace.
Replace.
Tighten.
Replace.
Tighten manifold bolts or nuts;
replace o-rings.
Tighten.
Replace.
Tighten.
Replace.
Tighten clamp nuts.
Inspect; replace.
Inspect; replace.