Internal Shaft Dimensions - Viessmann Vitodens 100-W Technical Manual

Flue systems for gas condensing boilers vitodens series; vitosolar series up to 150.0 kw
Hide thumbs Also See for Vitodens 100-W:
Table of Contents

Advertisement

Design and sizing information for connection on the flue gas side

Internal shaft dimensions

a
2
b
Minimum internal shaft dimensions
System size A
60 (rigid)
60 (flexible, shaft cover PPs)
60 (flexible, shaft cover metal)
80 (rigid)
80 (flexible, shaft cover PPs)
80 (flexible, shaft cover metal)
110 (rigid)
110 (flexible, shaft cover PPs)
110 (flexible, shaft cover metal)
125 (rigid)
160 (rigid)
200 (rigid)
250 (rigid)
Max. number of bends:
■ 87°: 3 pce
or
■ 45°: 3 pce
VIESMANN
36
a
c
External diameter, fe-
male connection
a
Ø mm
73
72
87
94
102
116
128
127
142
145
184
227
273
or
■ 30°: 4 pce
or
■ 15°: 4 pce
(cont.)
Minimum internal shaft dimensions
b
c
Square or rectangular
Round
(short side)
mm
Ø mm
113
133
112
132
140
147
135
155
142
162
165
176
170
190
167
187
182
202
185
205
224
244
267
287
313
333
VITODENS, VITOSOLAR