Seco DS9000 Installation & Operation Manual page 28

Ac drive digital speed controller
Table of Contents

Advertisement

2. While in PROG Mode, use the Value/Code Key to change between the parameter name and the
value stored in that parameter. With PS1 showing on the display, the Value/Code key will toggle
between PS1 and its stored value. If the value is not zero, use the DOWN key to change it to zero.
The Hi/Low key changes the sensitivity of your adjustment to either units of 100 to 1. When the
"Hi Adjust" LED is displayed, the UP or DOWN key changes the value in units 100. By pressing
the HI/LOW key, the "HI ADJUST" LED turns off and the "LOW ADJUST" LED turns on. Now
you can change the value by units of 1. Once you have set the value to the desired value, press
Value/Code so that PS1 is displayed.
3. To check the rest of the parameters, press the UP key to step to the next parameter. PS2 will be
displayed. Press Value/Code to see the value. Press Value/Code again to display PS2. Only press
the UP or DOWN key when the parameter name is showing. If you press the UP or DOWN key
when the value is showing, you will change that value. Step through the parameters and check the
values using this list.
PARAMETER CODE
PS1
PS2 - - - - - - - -
PS3
PS4 - - - - - - - -
L0
HI - - - - - - - -
ACE1
dDE1 - - - - - - - -
FDd0
SCF0 - - - - - - - -
SCd0
P E
I E
POSE
FEd1
SCF1 - - - - - - - -
SCd1
4. In Set-Point mode, Parameters FEd1, SCF1, SCd1, and POSE will not be displayed since they are
only applicable in Follower mode. In Follower mode, ACE1 or dEC1 will not be displayed since
they have no effect in this mode. Also, in Follower mode, the LO Boundary is a maximum of (HI -
.001) and a minimum value of 0. The HI boundary is a maximum of 9.999 and minimum value of
(LO + .001).
5. To lock in these parameters, connect TB1-6 to circuit common,, TB1-9 or TB1-12.
6. If the parameters have been changed and you would like to change them back to their original
default values, you could either change the parameters individually or follow the following steps
to change all of them at once.
Step 1
Turn off AC power to the DS9000
Step 2
Press and hold down the PROG key and the Value/Code key.
Step 3
While holding these two keys, turn on the AC power to the DS9000.
Step 4
Release the PROG and Value/Code keys.
The parameters have been changed back to their default values. Both Parameter Data
Tables A and B will be reset to the default values as listed in 2.7.3 number 3.
2.7.4
Scaling the Motor Speed, Open Loop Control
To ensure proper speed scaling of the motor controller and the DS9000, the first step is to operate the
system in an "open loop" mode. The DS9000 will provide a 0-10 VDC speed input signal just like a
DEFAULT VALUE
0
0 - - - -
0
0
0 - - - -
1800
3.0
3.0 - - - -
60
1800 - - - -
0
200 - - - -
300
10 - - - -
60
1800 - - - -
0
MAX. VALUE
HI
HI
HI
SCFO
1/3 OF SCFO
SCFO
999.9
999.9
600
9999
3
2000
2000
300
600
9999
3
MIN. VALUE
LO
LO
LO
0
0
1/3 OF SCFO
0.1
0.1
90
100
0
50
50
5
30
100
0
27