Software Revision Number; Terminal Strip Connections - Seco DS9000 Installation & Operation Manual

Ac drive digital speed controller
Table of Contents

Advertisement

2.7.1.6

SOFTWARE REVISION NUMBER

DipSW6
OFF – No Effect
ON – Upon application of AC power, the LED Readout will display the software
revision number
2.7.2

TERMINAL STRIP CONNECTIONS

In the first section of this manual, Introduction/Product Description, section 1.7.2 defined the
terminal strip designations. The power input, motor controller interface, motor feedback pulse
generator and master reference pulse generator signals are connected to the DS9000 via the rear panel
terminal strips. Refer to Figures 2.2 and 2.3 for typical connections.
AC Input
For 115 VAC input:
Jumper TB2-1 to TB2-2
Jumper TB2-3 to TB2-4
Connect 115V AC input to BLUE and BROWN conductors of supplied AC input cable.
For 230 VAC input:
Jumper TB2-2 to TB2-3
Connect 230V AC input to BLUE and BROWN conductors of supplied AC input cable.
Motor Feedback Signal
For the motor to be controlled by the DS9000, connect the pulse generator mounted on the motor to:
TB1-8
Feedback Signal Input
TB1-9
Feedback Signal Common
For Pulse Generators that require a +5V DC voltage source, such as Encoders and Hall Effect devices,
a +5V DC source has been provided.
TB1-10
+5VDC Supply Voltage (max 40ma)
Refer to Figure 2.4 for proper feedback connections.
Follower Reference Signal
The master reference pulse generator, which provides the master reference signal for a Master-
Follower Ratio System, is connected to:
TB1-11
Follower Reference Signal Input
TB1-12
Follower Reference Signal Common
Motor Controller Reference
The DS9000 sets the speed of the controlled motor via a 0-10 VDC analog output signal.
TB3-1
Isolated analog output, connects to the motor controller reference input (often
designated as W since this is where the wiper from a speed potentiometer would be
connected.
TB3-2
Isolated common, connects to the motor controller reference common (often
designated as CCW since the low side or counterclockwise side of a speed
potentiometer would be connected here).
Start/Stop Input
24

Advertisement

Table of Contents
loading

Related Products for Seco DS9000

This manual is also suitable for:

Ds9000a

Table of Contents