Close Timer For A Single Or Master Operator; Two-Way Adjustable Reverse Sensor / Erd - Eagle AVI Installation & Owner's Manual

Slide gate operator ul 325 class
Table of Contents

Advertisement

Close Timer for a Single or Master Operator

Switch #1 MUST be ON. Turn the close timer ON (Switch #4) and adjust the TIMER from 1 to 60 seconds (Single operator mode).
NOTE: See page 17 for
master/slave close timer setup.
Two-Way Adjustable Reverse Sensor / ERD Emergency Reversing Device
Proper function of reverse sensor (ERD):
When meeting an obstruction in the CLOSING direction, the gate will STOP, reverse direction and return to the FULL OPEN position.
When meeting an obstruction in the OPENING direction, the gate will STOP and reverse its direction and stop again after 4-6 inches. The gate
operator will stay in an "ERD OVERLOAD" state for 5 minutes or until manually reset (Reset button or power switch OFF/ON).
If the gate operator enters overload status two times in a row, the alarm will sound until manually reset.
OPENING
CLOSING
ERD CONTROL
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
OPEN
E
OPENING CLOSING CLOSED
BRAKE OFF
BRAKE ON
CLOSE TIMER OFF
CLOSE TIMER ON
OPENING
CLOSING
LIMIT
LIMIT
OFF—ON
FEATURE SELECTOR
TIMER
ERD CONTROL
GATE STATUS
S1 S2
FCN
0
1
ON ON
STOP N/C
ON OFF CLOSE
RESET
M/S PHASE
OFF ON
PHANTOM
OFF OFF EDGE SENSOR
MULTI FUNCTION
ERD OVERLOAD
#6
#7
#8
#9
SLAVE MASTER
+ –
+ –
INPUT/OUTPUT
INPUT/OUTPUT
COMM PORT
COMM PORT
POWER
ERD OVERLOAD
ERD OVE
ERD OVER
RD OV
RD OVE
RD OV
RD OVE
RD OVE
RD OVE
D OV
OVERLOAD LED:
The OVERLOAD
LED warning light will light up when
the gate is heavier than normal for the
operator. During this warning, the
operator will NOT function properly.
14
Feature Selector #1 and #4
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
OFF—ON
FEATURE SELECTOR
See page 11 for Features Selector.
Only a qualified service technician must make all adjustments to these sensors.
The Control Board has a sensitivity adjustment for the OPENING direction and CLOSING direction of
the gate. Both MUST be adjusted.
Adjustment must be made so that the gate stops and reverses when meeting an obstruction.
IMPORTANT:
The level of sensitivity has to do with the weight of the
gate and the condition of the installation. A heavier gate will require
LESS sensitivity and a lighter gate will require MORE sensitivity.
More
Sensitive
Opening
Gate
Direction
More
Force
Less
Force
must be ON.
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
TIMER
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
OPEN
OPENING CLOSING CLOSED
BRAKE OFF
BRAKE ON
CLOSE TIMER OFF
CLOSE TIMER ON
LIMIT
OPENING
CLOSING
OFF—ON
FEATURE SELECTOR
TIMER
ERD CONTROL
GATE STATUS
S1 S2
FCN
0
1
ON ON
STOP N/C
ON OFF CLOSE
M/S PHASE
RESET
OFF ON
PHANTOM
OFF OFF EDGE SENSOR
MULTI FUNCTION
ERD OVERLOAD
GND
#1
RCVR
24VAC
GND
#2
#3
#4
#5
#6
#7
#8
#9
SLAVE MASTER
+ –
+ –
INPUT/OUTPUT
COMM PORT
COMM PORT
CAUTION
When adjusting the sensors sensitivity:
TOO sensitive - If the gate stops or reverses by itself.
Less
Sensitive
NOT sensitive enough - If the gate strikes an object
Closing
and does NOT stop or reverse.
Gate
Direction
Factory Set ERD Sensor "Fine Tune" Adjustment:
Please call Eagle Access before adjusting this sensor!
Fine tune adjustment is ONLY necessary when stopping force
cannot be achieved within normal reverse sensor ERD range.
Less
Three (3) full turns sets ERD in the "Normal Range":
Force
• Turn Clockwise for MORE force beyond normal range.
• Turn Counter-Clockwise for LESS force than normal range.
More
Force
Clockwise increases close time.
LIMIT
POWER
AVI Slide Rev - C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents