120 Vac Input Power Connection; Setting The: Limit Nuts & Open Left Or Open Right - Eagle AVI Installation & Owner's Manual

Slide gate operator ul 325 class
Table of Contents

Advertisement

120 VAC Input Power Connection

Release Knob
Control
Board
Plate
Setting the: Limit Switches & Open Left or Open Right
CAUTION
Be sure that power is turned OFF.
Control
Board
Plate
Release
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
CLOSE TIMER OFF
CLOSE TIMER ON
OPENING
CLOSING
LIMIT
OFF—ON
FEATURE SELECTOR
TIMER
ERD CONTROL
S1 S2
FCN
0
1
ON ON
STOP N/C
ON OFF CLOSE
RESET
M/S PHASE
OFF ON
PHANTOM
OFF OFF EDGE SENSOR
MULTI FUNCTION
ERD OVERLOAD
GND
#1
RCVR
24VAC
GND
#2
#3
#4
#5
#6
#7
#8
SLAVE MASTER
+ –
INPUT/OUTPUT
12
Black wire to Black wire.
White wire to White wire.
Green wire to Green wire.
Removing Release Knob will
allow control board plate to be
rotated up and gain easier
access to limit box, see above.
The limit nuts MUST be set so the
Knob
gate stops at the correct open and close
positions. the control board MUST have power
for the limit LEDs when setting the limit nuts.
Adjust the close limit nut FIRST when the gate
is in the closed position.
OPEN
OPENING CLOSING CLOSED
LIMIT
GATE STATUS
OPEN LEFT
#9
+ –
COMM PORT
COMM PORT
POWER
CAUTION
Be sure that the circuit breaker for the input power is turned OFF
before connecting the input power to the operator.
All operators MUST be properly grounded.
Installing surge protection is recommended.
WARNING:
Eagle Access Control Systems, Inc. is not responsible for
researching and complying with local building codes. Be sure to check
all local building codes before installation.
Wire Color Description
120 VAC
Black - 120 VAC input power
White - Neutral input
Green - Ground input
(from an approved grounding method)
120 VAC Input Power Wire
14 AWG
12 AWG
Single Operator
250 ft
400 ft
Dual Operators
125 ft
200 ft
IMPORTANT: DO NOT
cycle the operator before
setting the limit nuts. Damage or injury could occur
if limit nuts are NOT set correctly. (See below)
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
CLOSE TIMER OFF
CLOSE TIMER ON
OFF—ON
FEATURE SELECTOR
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPENING CLOSING
CLOSE
CLOSE
CLOSE
CLOS
CLOSE
CLOSE
CLOSE
CLOSE
CLOSE
LOS
LIMIT
LIMIT
GATE STATUS
Limit
Limit
Nut LED
Nut LED
Indicates the direction
the gate is cycling.
10 AWG
8 AWG
4 AWG
650 ft
1000 ft
2000 ft
325 ft
500 ft
1000 ft
Limit Nut
Limit Nut
L o
c k i
n g
T a b
To Set the Limit Nuts:
With power turned ON, press and
hold spring loaded locking tab
and rotate limit nuts accordingly
until LEDs light. Make sure nuts
are locked in position after
releasing locking tab.
OPEN RIGHT