Network

6.2.1

Connection

Four extra tabs are available (External. Internal, Port, Streaming).
External
Input here the following network information:
MTU: Maximum transmission unit in bytes unit for used ports (default is 1500).
IP version: IPv4 (default) or IPv6. This is the IP address access format.
DHCP (only for IPv4 option): Select this to automatically search for IP details. If this field is
enabled, you cannot modify IP / Subnet mask / Gateway and these values are displayed as
zero (if PPPoE is operating, you also cannot modify IP/Subnet mask /Gateway). To view the
current IP information, you first need to disable the DHCP function.
Link address (only for IPv6 option): Network address that is valid only for communications
within the network segment (link) or the broadcast domain that the host is connected to.
IP address: Enter here your IP address. (For the IPv6 version, default gateway, preferred DNS
and alternate DNS, the default value shall be 64-digit).
Subnet mask (only for IPv4 option): Enter here your subnet mask address
Default gateway: If required, enter here the default gateway address.
Important
The system needs to check the validity of all IPv6 addresses. The IP address and the default
gateway must be the same in each IP section (i.e. the specified length of the subnet prefix
must have the same string).
The maximum number of connections is 64, however more than 4 remote connections
can cause performance limitations. Bosch strongly advises not using more than 4
simultaneous connections.
Preferred DNS: if required, enter here the preferred DNS server IP address.
Alternate DNS: if required, enter here an alternative DNS server address.
When ready, click <Save> to enter values and go back to the previous menu.
Internal
Choose here the settings for an internal network (DHCP or as a DHCP switch)
IP address: Enter here your IP address. (For the IPv6 version, default gateway, preferred DNS
and alternate DNS, the default value shall be 64-digit).
Subnet mask: (only for IPv4 option): Enter here your subnet mask address
Default gateway: If required, enter here the default gateway address.
Port
TCP port: Default is 37777.
UDP port: Default is 37778.
HTTP port: Default is 80.
HTTPS port: Default is 443.
RTSP port: (Default is 554). When setting up RTSP streaming, use the following URL format:
rtsp://<username>:<password>@<ip>:<port>/cam/realmonitor?
channel=<channelNo>&subtype=<typeNo>
e.g.: rtsp://ADMINISTRATOR:000000@10.120.19.60/cam/realmonitor?channel=1&subtype=0
username = username
password = password
port = default is 554 (this is optional)
channel = channel number 1..16
subtype = 0 or 1 (1
Bosch Security Systems
or 2
stream)
st
nd
Operation Manual
Available from A1 Security Cameras
www.a1securitycameras.com email: sales@a1securitycameras.com
Settings | en
33