UEi DL200 Instruction Manual

Catiii clamp meter and voltage tester

Advertisement

Quick Links

CATIII Clamp Meter and
Voltage Tester
INSTRUCTION MANUAL
ENGLISH
600V
CAT III
The DL200 is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the unit
will be repaired or replaced at UEi's option. This warranty covers normal use
and does not cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
CAUTION: This symbol indicates that equipment and its accessories
shall be subject to separate collection and correct disposal.
Periodically clean your meter's case using a damp cloth. DO NOT use abrasive,
flammable liquids, cleaning solvents, or strong detergents as they may damage the
finish, impair safety, or affect the reliability of the structural components.
Remove the batteries when instrument is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications section, allow
the instrument to return to normal operating conditions before using it.
Copyright © 2016 UEi. All Rights Reserved.
DL200

WARRANTY

DISPOSAL

CLEANING

STORAGE

99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
600V
CAT III
200A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for UEi DL200

  • Page 1 Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
  • Page 2: General Specifications

    FEATURES • 600V AC/DC • 200A AC • 2000Ω Resistance • Audible continuity • Data hold • Auto ranging • Low battery indicator • Auto power off • Permanent test leads • Storage for test leads • Auto calibration • Latches for battery compartment GENERAL SPECIFICATIONS •...
  • Page 3 SYMBOLS AC (Alternating current) DC (Direct current) AC/DC Polarity Overload: Range Exceeded Auto power off active Low Battery Hold/Capture Value Voltage Amperage Ohms/Resistance Continuity High Voltage Indication Warning or Caution Ground Dangerous Levels Double Insulation Safe for disconnect from (Protection to Class II) live conductors CATEGORY DEFINITIONS Measurement...
  • Page 4 Auto On/APO 600V CAT III 200A HOLD • Default = • Press x1 = • Press x2 = • Press any button to power on meter. • Press and hold AC/DC Volts/Power button to power off meter. • Auto power off (Apo) after 10 minutes of inactivity. •...
  • Page 5 CATIV 600V • The DL200 is CATIII rated to IEC 61010-1 3rd edition standards. Do not attempt to measure in locations that requires a CATIV rated meter. Remove the CATIV test lead caps and use the CATIII 1000V test lead measurement locations.
  • Page 6 Battery Replacement S/N: OPEN LOCK OPEN LOCK • When the batteries are too low for safe operation, the Low Battery indicator will display. • Rotate latches until Unlock symbols are aligned with arrows. Remove battery cover. • Replace the old batteries with 2 new (AAA) batteries. •...

Table of Contents