5. A dual position cable clamp is provided. For
top cable entry use retaining bar in horizontal
position supplied. For bottom cable entry
rotate retaining bar to the angled position.
6.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
7. The earth
8mm
continuity
5mm
conductor of
10mm
the electrical
installation
33mm
MUST BE
effectively
connected
electrically to all exposed parts of the
appliances and services in the room in which
the water heater is to be installed in conformity
with the current BS. 7671 (I.E.E. wiring
regulations).
FINAL INSTALLATION PROCEDURE
AND COMMISSIONING
WARNING : DO NOT SWITCH ON THE
ELECTRICITY SUPPLY UNTIL THE
FOLLOWING PROCEDURE HAS BEEN
COMPLETED. FAILURE TO DO SO COULD
CAUSE THE PUMP TO RUN DRY AND
INVALIDATE THE GUARANTEE.
1. Fit the front cover back into position, ensuring
that both the control knobs are correctly
aligned with the flow valve and power selector.
Secure with top and bottom screws.
2. Fit hose and prime the shower first without the
handset to flush out any remaining debris. To
prime the shower ensure that the electricity
supply is switched off. Turn control knob 'B'
fully anti-clockwise. Water should start to flow
with motor switched off allowing all the air to
be purged out of the shower unit.
It may be necessary to lower the hose
below the level of the shower unit whilst
priming.
Stop water flow by turning knob 'B' fully
clockwise. Attach handset, switch on electrical
supply and then operate the shower as on
page 2 and check–
a) That the water gets to a satisfactory
temperature
b) Water flow can be adjusted by knob 'B'
c) Power selection operates in both positions,
giving a change in water temperature
d) Check again for leaks
e) That the holes in the spray plate are not
blocked
f) That the motor turns off and water stops
flowing in the 'STOP' position
10mm
3. DEMONSTRATE OPERATION TO THE USER
Live
Please leave these instructions with the user
Earth
for future reference.
Neutral

ADDITIONAL ACCESSORIES

Diagram 10
White 2 metre shower hose
1 metre riser rail
Water control tap
Shower de-scaling powder
Curtain and rail pack
Curtain and rail pack with non
slip bath mat
Spare parts/accessories can be supplied
against any Visa or Access cards from
Redring Sales 01733 456700.
INLET ASSEMBLY SHOWING FILTER
POSITION
Diagram 11
Cat. No.
83-593529
83-593530
93-792452
95-711015
83-792802
83-792801
9