Konica Minolta CL-70F Quick Manual
Konica Minolta CL-70F Quick Manual

Konica Minolta CL-70F Quick Manual

Cri illuminance meter
Hide thumbs Also See for CL-70F:

Advertisement

Quick Links

CRI Illuminance Meter
CL-70F
Quick Guide
Thank you for purchasing a CRI Illuminance Meter CL-70F
ank y
for p chas
a CR
lumi
nce M er CL
This
s Quick Guide introduces the basic operation for this instrument.
ick G
e int
uces
bas
perat
for t
instr
Please refer to "Operating Manual" on the CD-ROM (included
Plea
ase r
refe
r to
"Op
perat
ting
Man
nual
on
n the D-RO
e CD
OM (i
inclu
uded
product) for usage details.
duct
r us
deta
.
4
.
Input of Figures/Characters
Figure Input
Upper Case Input
Lower Case Input
Screen
Screen
Screen
Preset Name
Preset Name
Preset Name
4
4
4
3
3
3
2
2
2
5
5
5
1
1
1
6
7
6
7
6
2
2
4
6
5
1
3
7
6
5
1
3
7
Input Method of Characters and Figures
(Character Setting Screen, Figure Setting Screen)
No.
Key
Description
1
1/A/a
0-9, ABC,
Touching it displays an input value in the upper section.
2
abc, hyphen,
By touching the same button multiple times, you can
period
change the character input to the English alphabet (ABC).
3
Delete
Deletes the character at the cursored position.
4
Moves input position.
5
Keypad
Shifts between Standard Keypad and Qwerty Keypad.
6
OK
7
Cancel
Cancels the input and returns to the original screen.
1
.
This instrument and the following accessories are included.
Quick Guide
- Operating Manual
- CRI Illuminance
Safety Precaution Neck Strap
Soft Case
English
Safety Precaution
For Proper Operation
Before using this product, please read this "Safety Precautions" for
proper operation.
WARNING
The WARNING symbol indicates the
possibility of death or serious injury if the
Authorized Service Facility
product is not used properly.
The CAUTION symbol indicates the
CAUTION
possibility of minor to moderate personal
injury or product damage if the product is
not used properly.
The NOTICE symbol indicates cautions
NOTICE
or restrictions when using the product.
Please read all notes to avoid errors in
operation.
General Safety Information
Read the Operating Manual before use.
Keep the Operating Manual on hand for reference at any
time.
Stop using this product when there are any abnormalities.
Do not attempt to repair this product by yourself.
This product is intended only for persons with expert
knowledge.
Monitor children so that they do not touch this product.
Use this product in a usage environment described in the
Operating Manual.
This product is not waterproof.
* If something is missing, contact the sales agent.
* Batteries (size AA) and a USB cable are not included. Please prepare
them in advance yourself.
* The "CRI Illuminance Meter CL-70F", included as an accessory of this
product, can be used to save data, display memorized values and graphs,
and perform settings when the meter is connected by USB to computers
or tablets.
5
.
Turning the Power ON
After installing the batteries, turn the Light Selection Ring
2
to the dark calibration position (
) and turn ON this
instrument by pressing the Power Button 3.
After the Opening screen displays (for 2 seconds) in the
Display Panel, dark calibration starts. After dark calibration
properly ends, the Display Mode Selection screen displays.
Set to the dark calibration position. Press Power Button 3.
Display Mode Selection
Light Selection Ring
2
Opening Screen
7
4
Power Button
3
*
Light Selection Ring
2
to Dark Calibration position and perform
calibration again.
* To turn OFF the power, press and hold the Power Button for more
than one second.
* Please wait 3 or more seconds between turning the power ON/OFF.
2
.
Part Designations
The part designations are as follows.
1
Light Receptor
CD-ROM
2
Light Selection
Ring
3
4
Display Panel
5
Meter CL-70F Utility
0
Tripod Socket
7
8
9
Inspection
6
Inspection
Certificate
CRI Illuminance Meter
PRODUCT
MODEL
CL-70F
SERIAL NO.
This is to certify that the above product has
been inspected with the results listed on the
inspection standards of this company.
reverse and has be en found to satisfy the
Inspector :
9229-A8FG-11
c
Strap Eyelet
a
d
b
Sync Terminal
Dark Calibration Position
* If "Please set Light Selection Ring for
dark calibration" is displayed, set the
Light Selection Ring
calibration position to start calibration.
* When taking measurements, set the
Light Selection Ring
(icon at the middle) for ALL ambient light.
at the top) for high-power (brighter
Screen (2°)
than 640lx·s).
Select a language used when you turn on the power for the
The language selected will be displayed and encircled in
Language Selection
Screen
3
.
Operation Method
The operation method of this instrument's Display Panel is
described.
setting or item.
(Ex.) Shutter Speed Selection Screen
Scroll Selection
or down on the
setting value areas
to change setting
values.
One Step Icon
Touch Up or Down
Icon to advance one
position.
Tabs
* A blue illumination under
icons indicates which icons
are operational.
6
-1.
Measurement Preparation
(Measuring Mode, Display Mode)
You can change screens after turning the power on as follows.
Changes from the Display Mode Selection Screen to the
2
to the dark
Measurement Screen.
* Pressing Menu Button
6
2
to the range L
Display Mode
Measurement Screen
Selection Screen
Language Selection
Measuring Mode Icon
Ambient Light
Mode
Flash Light
Cordless Mode
Flash Light
Cord (PC) Mode
Top Icon
Touch to advance
to the lowest
value.
Touch and slide
up or down to
scroll settings.
Touch to advance
to the highest
value.
* Blue bar indicates value
selected.
shifts to the Display Mode Selection screen.
Measuring Mode
(Text Mode)
Selection Screen
Description
Measures continuous light such as
lights.
pressed to arm meter for 90 seconds

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CL-70F and is the answer not in the manual?

Questions and answers

Summary of Contents for Konica Minolta CL-70F

  • Page 1 Quick Guide introduces the basic operation for this instrument. ick G e int uces perat for t instr * The "CRI Illuminance Meter CL-70F", included as an accessory of this Please refer to "Operating Manual" on the CD-ROM (included Plea ase r refe r to "Op...
  • Page 2 Display Mode Customizing Measuring Displays Functions Setting You can customize displayed information to see exactly )" icon in any measurement Touching the "Setting" icon in the Display Mode Selection to take a measurement in each what you need in single view. A blue illumination under Display Mode.

Table of Contents