Olsberg CTSC User Manual page 25

Standard heater
Hide thumbs Also See for CTSC:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
LCD display
This is used to communicate with the control unit. As soon as any button or rotary knob is activated, the display will
be backlit. The backlighting will be de-activated if idle for around 15 seconds.
Target charge level, rotary knob
By turning the knob the target charge level can be adjusted; it will be stored directly as a control variable.
Target room temperature, rotary knob
The target room temperature can be adjusted by turning the knob; it will be stored directly as a control variable.
OK button
For use when entering a menu item and confirming an entry in the menu.
Button +
Increases a value in the menu. That value will then flash.
Button -
Decreases a value in the menu. That value will then flash.
LED control lights
- Red (left), lights up when the appliance is charging.
- Green (centre), lights up when fan clearance has been activated.
- Orange (right), lights up when supplementary charging has been activated.
Menu button
Menu item selection (see "Menu selection" chapter)
Die The procedure is always identical. Use the menu button to select a menu item. In order to edit this menu item,
confirm using 'OK'. Then either a dialogue box will appear, showing which button should be used to activate which
function, or you will be taken directly to a display showing a flashing value. A flashing value can be changed using
+/-; this must then be confirmed using 'OK'. Once you are in a menu item, you can exit it by pressing the menu
button (or by waiting for 30 seconds).
Fan button
Manual fan clearance
The electronic control system must receive a clearance message for the fan to start. This can be issued manually
using this button, or automatically by programming switch points (see chapter on "Fan programme"). If you use the
manual option, please remember that the fan clearance will remain activated until you deactivate it. Therefore, you
should only choose this operating mode if you intend mainly discharging the appliance statically (i.e. without fan
operation), and only intend to switch on the fan occasionally. The green LED above the button will light up once fan
clearance has been activated (manually or programmed).
Supplementary charge button
This button is used to activate a daytime charge (i.e. at peak rates). Once this has been activated, the orange LED
above the button will light up. Since charging is involved, the red LED will also light up. After a maximum of 2
hours, or once a 35% charge level has been reached, the supplementary charge will automatically be de-activated.
This function has been provided in case more heat is unexpectedly required than had been charged on the previ-
ous day.
Indication Child-proofing
If child-proofing is active, it can be seen in the display (Fig.1a). All buttons are without function.
Indication Current charge level
The current charge level is indicated in the display (Fig.1a).
Indication Day / time
The actual day and time is indicated in the display (Fig.1a).
Indication Fan clearance programme
If a fan clearance programme is activated, it can be seen in the display (Fig.1a).
Indication Charge level reduction
If a charge level reduction programme is activated, it can be seen in the display (Fig.1a).
25

Advertisement

Table of Contents
loading

Table of Contents