3.2.3

Adjustment of the Exit Motor (M3-FN) Timing Belt

[1]
[1]
3.3

Adjustment of the Elevator Tray Upper Limit Sensor

1. Set up the sensor test mode.
2. Turn VR1 on PWB-A FN fully counterclockwise.
3. Using a sheet of paper, block the Elevator Tray Upper Limit Sensor LED (PWB-C FN).
4. Check that LED4 on PWB-A FN turns OFF. If it stays ON, slowly turn VR1 clockwise
and stop turning it as soon as the LED turns OFF.
1. Loosen three screws [1].
[1]
2. Tighten three screws [1] so that the
[2]
4684fs2507c0
Mechanical adjustment
distance D between the upper end
face of the head of screws [1] and
the upper end face of the slot in the
mounting bracket [2] measures
about 0.5 mm.
[1]
[2]
4684fs2509c0