Foot Valve/Suction Tubing Installation - LMI PW5 Instruction Manual

Series aa, b, c, e, j5, and p electronic metering pumps
Hide thumbs Also See for PW5:
Table of Contents

Advertisement

4.7

Foot Valve/Suction Tubing Installation

The Foot Valve acts as a check valve to keep the pump primed
in suction lift applications.
The foot valve is designed to be submersed in the solution tank
or drum and must sit in a vertical position at the bottom. Position
approximately 2 inches (50 mm) off the bottom if the tank or
drum contains sediment.
Pump models equipped with high-viscosity liquid ends are not
equipped with foot valves. Flooded suction is recommended. A 1/2"
NPT connector is included for flooded suction installations.
The ceramic weight, when installed, positions the foot valve in a
vertical position.
1.
Attach the foot valve to one end of the suction tubing (see
Tubing Connections, Section 4.3).
2.
Slide the ceramic weight over the tubing end until it contacts
the top of the foot valve coupling nut.
3.
Place foot valve and tubing into the solution tank. Check that
the foot valve is vertical and approximately 2 inches (50 mm)
from the bottom of the tank or drum (see illustration). Connect
the other end of the tubing to the suction side of the pump
head (bottom side) (see Tubing Connections, Section 4.3).
Foot Valve
Tilted Sideways WILL NOT PRIME
INCORRECT
20
LMI
Pump
for Sediment Accumulation
Proper Foot Valve Position
LMI
Pump
2.0 in. (50 mm)
CORRECT
Use Ceramic
Weight
Foot Valve
Must Remain
Vertical