Olympus BF-P190 Instructions Manual page 25

Bronchovideoscope
Table of Contents

Advertisement

No.
Nomenclature
1
UP/DOWN
When this lever is operated in the "U" direction, the bending section moves UP; when
angulation control
the lever is operated in the "D" direction, the bending section moves DOWN.
lever
2
Single use suction
The suction valve is depressed to activate suction. The valve is also used to remove any
valve (MAJ-209) or
fluid or debris adhering to the objective lens.
suction valve
*1
(MAJ-207
)
3
Control section
Operates the endoscope, such as controlling angulation.
4
Single use biopsy
This valve is attached to the instrument channel port, and an EndoTherapy accessory
valve (MAJ-210) or
can be inserted or a syringe can be attached.
biopsy valve
*1
(MD-495
)
5
Instrument channel
An EndoTherapy accessory can be inserted into this port. The instrument channel inlet
inlet
is connected to the instrument channel outlet on the distal end via the instrument
channel.
The instrument channel functions are as follows:
• Channel for the insertion of EndoTherapy accessories
• Suction channel
• Fluid feed channel (from a syringe via the biopsy valve)
6
Instrument channel
Attach the biopsy valve to this port.
port
7
Color code
This color code and numeral show the compatibility of EndoTherapy accessories.
• Blue: BF-Q190, BF-H190, BF-P190
• Yellow: BF-1TH190
• White: BF-XP190
The endoscope can be used with EndoTherapy accessories that have the same color
code. For more information on combining the endoscope with particular EndoTherapy
accessories, refer to "Combination equipment" on page 83 and the instruction manuals
for the compatible accessories.
8
Boot
Protects the junction between the insertion tube and control section from bending.
9
Insertion section
This section is inserted into the patient body cavity. It can be rotated to the left and right
at angles up to 120 respectively on the control section by rotating the insertion tube
rotation ring.
10
Distal end
The objective lens and light guide lens are on this distal end.
11
Bending section
The bending section moves the distal end of the endoscope when the UP/DOWN
angulation control lever is operated.
12
Insertion tube
Connects the control section and bending section.
13
Remote switches 1
The functions of the remote switches 1 to 4 can be selected on the video system center.
to 4
Refer to the instruction manual for the video system center when setting these functions.
14
Suction cylinder
Attach the suction valve to this cylinder.
*1 These products may not be available in some areas.
BF-190 Series OPERATION MANUAL
2.1 Nomenclature and functions