INSTRUCTIONS
BX3-SSU
SCANNING STAGE WITH ULTRASONIC
Optical Microscope Accessory
This instruction manual is for the Olympus Scanning Stage with Ultrasonic Model BX3-SSU.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use
[TYPE-2]
of the scanning stage with ultrasonic, we recommend that you study this manual thoroughly
before operating the microscope. In addition, be also sure to read the instruction manual for the
microscope on which the scanning stage with ultrasonic is installed.
Retain this instruction manual in an easily accessible place near the work desk for future reference.
A X 8 2 1 3
Downloaded from
ManualsNet.com
search engine

Advertisement

Table of Contents
loading

Summary of Contents for Olympus BX3-SSU

  • Page 1 BX3-SSU SCANNING STAGE WITH ULTRASONIC Optical Microscope Accessory This instruction manual is for the Olympus Scanning Stage with Ultrasonic Model BX3-SSU. To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use [TYPE-2] of the scanning stage with ultrasonic, we recommend that you study this manual thoroughly before operating the microscope.
  • Page 2 Refer to your local Olympus distributor in EU for return and/or collection systems available in your country. NOTE: This product has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 3: Table Of Contents

    BX3-SSU CONTENTS IMPORTANT -- Be sure to read this section for safe use of the equipment. -- MODULE NOMENCLATURE CONTROLS OPERATION OF SCANNING STAGE WITH ULTRASONIC Turning the Power ON Moving the Stage Replacing the Fuses COMPENSATION OF THE STAGE ..................................
  • Page 4: Important -- Be Sure To Read This Section For Safe Use Of The Equipment

    2. To prevent obstruction of the air vents 2 on both sides of the control box @ for BX3-SSU, always install it longitudinally and make sure to leave at least 10 cm of free spaces around them.
  • Page 5 (1) Near an air intake or outlet of an air conditioning facility, etc. (2) Place subject to important vibrations or changes in temperature. (3) Near a source (including equipment not manufactured by Olympus) of abnormal noise. (4) Place subject to direct sunlight.
  • Page 6: Module Nomenclature

    MODULE NOMENCLATURE } To ensure the performance, we recommend that you have your Olympus representative assemble and adjust the scanning stage with ultrasonic. The modules marked * are not part of the scanning stage with ultrasonic product. Microscope frame* BX63F...
  • Page 7: Controls

    Optional accessories Stage clips IX-SCL Center plate with 50 mm hole IX-CP50 Supersonic stage control box (Provided with BX3-SSU) DRIVE connector RS232C connector SENSOR connector MCXY connector Pilot lamp Main switch TRIG-OUT connector Fuse box (P.
  • Page 8 XY controller (Provided with BX3-SSU) Y-axis knob* X-axis knob* Coarse/fine selector button Pushed in: Coarse adjustment. Out position: Fine adjustment. * The factory settings of the stage displacement per turn are 10 mm for the coarse adjustment and 0.2 mm for the fine adjustment.
  • Page 9: Operation Of Scanning Stage With Ultrasonic

    BX3-SSU OPERATION OF SCANNING STAGE WITH ULTRASONIC When you use BX3-SSU for the first time, be sure to perform the Compensation of the stage. For detail procedures, refer to “4 Compensation of the Stage” described in the next page. Turning the Power ON (Fig.
  • Page 10: Compensation Of The Stage

    If the foreign substance is entered in the stage driving part, CAUTION the status may not be recovered by performing the Auto Compensation. In this case, turn the power of BX3-SSU Control Box to “ ” (OFF), and perform the Auto Compensation again after moving the stage from front to back and from side to side Fig.
  • Page 11: When Using Ix83

    If the foreign substance is entered in the stage driving part, CAUTION the status may not be recovered by performing the Auto Compensation. In this case, turn the power of BX3-SSU Control Box to “ ” (OFF), and perform the Auto Compensation again after moving the stage from front to back and from side to side Fig.
  • Page 12: Optional Accessories

    OPTIONAL ACCESSORIES Center Plate with 50mm Hole IX-CP50 } When observing the wide range on the specimen in a large container, etc., use the center plate with 50mm hole IX-CP50. Be careful not to drop or apply a strong impact to the stage CAUTION center plate.
  • Page 13: Specifications

    Applicable microscope frame BX63F, IX83P1ZF, IX83P2ZF, IX73P1F, IX73P2F, BX51WIF Slide glass specimen x 2 (total thickness 0.9 to 1.2 mm, cover glass thickness Slide holder 0.17 mm) Center plate with 25 mm hole (BX3-SSU accessory) Stage center plate Center plate with 50 mm hole IX-CP50 (option) Stage clips IX2-SCL.
  • Page 14: Troubleshooting Guide

    Under certain conditions, performance of the scanning stage with ultrasonic may be adversely affected by factors other than defects. If problems occur, please review the following list and take remedial action as needed. If you cannot solve the problem after checking the entire list, please contact your local Olympus representative for assistance. Problem...
  • Page 15: Assembly

    · Connect only the designated modules. Connecting a non-designated module may cause malfunction. · Be sure to set the main switches of the BX3-CBH/IX3-CBH and control box for BX3-SSU to “ ” (OFF) before connecting the cables.
  • Page 16 (Fig. 12) 1. Place BX3-SSU over BX63 so that the respective screw numbers (see the Fig. 6) of BX3-SSU and BX63 are overlapped. 2. Tighten the screw hole @ with the clamping screw (attached with BX3-SSU) from the upper side of BX3-SSU. Use Allen wrench (40x70mm) attached with BX63 for tightening.
  • Page 17 Fig. 14 3. Place the stage on the microscope so that the screw holes 4 of BX3-SSU overlaps the shim rings 3. And tighten the holes with the fixising screw 5 by using the Allen wrench provided with the microscope.
  • Page 18 Only for IX83 or IX73 5. Bundle BX3-SSU cables at the position 320mm from the edge on the stage side with the cable binder 8 provided with BX3-SSU. Fig. 17 6. Attach the cable holder 9 provided with BX3-SSU on the microscope.
  • Page 19 · Cables and cords are vulnerable when bent or twisted. Never subject them to excessive force. · Always use the power cord provided by Olympus. If no power cord is provided, please select the proper power cord by referring to the section “PROPER SELECTION OF THE POWER SUPPLY CORD”...
  • Page 20: Proper Selection Of The Power Supply Cord

    If no power supply cord is provided, please select the proper power supply cord for the equipment by referring to “ Specifications ” and “ Certified Cord ” below: CAUTION: In case you use a non-approved power supply cord for Olympus products, Olympus can no longer warrant the electrical safety of the equipment.
  • Page 21 BX3-SSU Table 2 HAR Flexible Cord APPROVAL ORGANIZATIONS AND CORDAGE HARMONIZATION MARKING METHODS Alternative Marking Utilizing Printed or Embossed Harmoni- Black-Red-Yellow Thread (Length zation Marking (May be located of color section in mm) Approval Organization on jacket or insulation of internal...
  • Page 22 MEMO Downloaded from ManualsNet.com search engine...
  • Page 23 Downloaded from ManualsNet.com search engine...
  • Page 24 Manufactured by Shinjuku Monolith, 2-3-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo 163-0914, Japan Distributed by 48 Woerd Avenue Waltham, MA 02453, U.S.A. 8F Olympus Tower, 446 Bongeunsa-ro, Gangnam-gu, Seoul, 06153 Korea Printed in Japan 2016 212 M0000 AX8213 06 Downloaded from ManualsNet.com...

Table of Contents