Kenwood NX-5800 Service Manual page 50

Uhf digital transceiver
Hide thumbs Also See for NX-5800:
Table of Contents

Advertisement

Item
Condition
Panel tuning
mode
13.
1) Adj item: [ADEV]
Maxi-
Adjust:[****]
mum
Deviation meter
Devia-
LPF: 15kHz
tion
HPF: OFF
*2
2) Adj item:
[Low1]→
[Analog
[Low3]→
Wide]
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
[Analog
1) Adj item:
Narrow]
[An ADEV]
Adjust:[****]
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
*2 : Refer to the "4.9.1 Necessary Deviation adjustment item for each signaling and mode" table.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
1-50 (No.RA017<Rev.002>)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Devia-
[Maxmum Devia-
tion
tion (Analog Wide)]
meter
Deviation meter
Oscil-
LPF: 15kHz
lo-
HPF: OFF
scope
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item:
Devia-
[Maxmum Devia-
tion
tion (Analog Nar-
meter
row)]
Oscil-
2) Adj item:
lo-
[Low1]→
scope
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Adjustment
Method
Write fixed value for
4150~4250Hz
each adjustment point.
(The value is written be-
[PC test
low.) Transmit at each
mode]
adjustment point and
Press [Apply
check that the deviation
All] button to
is between 4150Hz and
store the
4250Hz.
adjustment
Deviation meter
value after all
LPF: 15kHz
adjustment
HPF: OFF
points have
been adjusted.
505 (F,K)
503 (F2,K2)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Write fixed value for
2050~2150Hz
each adjustment point.
(The value is written be-
[PC test
low.) Transmit at each
mode]
adjustment point and
Press [Apply
check that the deviation
All] button to
is between 2050Hz and
store the
2150Hz.
adjustment
Deviation meter
value after all
LPF: 15kHz
adjustment
HPF: OFF
points have
been adjusted.
505 (F,K)
499 (F2,K2)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Specifica-
tions
/Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-5800(b)