Kenwood NX-5800 Service Manual page 51

Uhf digital transceiver
Hide thumbs Also See for NX-5800:
Table of Contents

Advertisement

Item
Condition
Panel tuning
mode
14. P25
1) Adj item:
High
[P1 PDEV]
Devia-
Adjust:[****]
tion
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
15. P25
1) Adj item:
H-CPM
[P2 P2DEV]
Devia-
Adjust:[****]
tion
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Devia-
[P25 High Devia-
tion
tion]
meter
Deviation meter
Oscil-
LPF: 3kHz
lo-
HPF: OFF
scope
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item:
Devia-
[P25 H-CPM Devi-
tion
ation]
meter
Deviation meter
Oscil-
LPF: 3kHz
lo-
HPF: OFF
scope
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Adjustment
Method
Write fixed value for
2771~2883Hz
each adjustment point.
(The value is written be-
[PC test
low.) Transmit at each
mode]
adjustment point and
Press [Apply
check that the deviation
All] button to
is between 2771Hz and
store the
2883Hz.
adjustment
Deviation meter
value after all
LPF: 3kHz
adjustment
HPF: OFF
points have
been adjusted.
505 (F,K)
504 (F2,K2)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Write fixed value for
3090~3215Hz
each adjustment point.
(The value is written be-
[PC test
low.) Transmit at each
mode]
adjustment point and
Press [Apply
check that the deviation
All] button to
is between 3090Hz and
store the
3215Hz.
adjustment
Deviation meter
value after all
LPF: 3kHz
adjustment
HPF: OFF
points have
been adjusted.
485 (F,K)
483 (F2,K2)
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
(No.RA017<Rev.002>)1-51