Kenwood NX-5800 Service Manual page 49

Uhf digital transceiver
Hide thumbs Also See for NX-5800:
Table of Contents

Advertisement

Item
Condition
Panel tuning
mode
11.
1) Adj item:
Low
[L_PWR]
Trans-
Adjust:[****]
mit
2) Adj item:
Power
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
12.
1) Adj item:
Balance
[Balance]
*1
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
*1 : Refer to the "4.9.1 Necessary Deviation adjustment item for each signaling and mode" table.
Balance adjustment is common with the adjustment of all signaling deviations.
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Power
[Low Transmit
meter
Power]
Ammeter
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item:
Devia-
[Balance]
tion
Deviation meter
meter
LPF: 3kHz
Oscillo-
HPF: OFF
scope
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Adjustment
Method
5W
±0.5W
10A or less
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
The Deviation of 20Hz
2kHz Tone de-
frequency is fixed.
viation is with-
Change the 2kHz ad-
in ± 1.0% of
justment value to be-
20Hz tone de-
come the same
viation.
deviation of 20Hz within
the specified range.
[PC test
mode]
(a supplementary
Press [Apply
explanation:
All] button to
Another way to adjust is
store the
ready.
adjustment
(Same as TK-5810, the
value after all
old model of NX-5800).
adjustment
Press [AUX(Orange)]
points have
key to switch the tone to
been adjusted.
100Hz square wave.
Then, make the demod-
ulation waveform shown
on oscilloscope into
square shape.)
(No.RA017<Rev.002>)1-49
Specifica-
tions
/Remarks