Control Panel Sw Itches; Control Board - Lennox Merit MPE36 Service Manual

Merit series
Table of Contents

Advertisement

Continuity test: control
panel switches
Earlier production models of the
MPE-36R have switches that
were soldered to their wires
rather than the push on
connector that are used on later
models.
To test these soldered switches:
See page 21 of the manual for the
location of the sw itch connector at
the control board.
Remove the connector from the

control board.

Set your multimeter to Ohms and
conduct a continuity test of the
w ires and sw itch.
When the sw itch is "off"/open the
multimeter w ill display "1" .
When the sw itch is "on"/closed the
multimeter should display a
measure of resistance (0.1
approx.)
If the multimeter displays "1" with
the switch in the "on" setting, the
switch is defective and must be
replaced.
If you suspect a defective
switch, test the switch 6 – 10
times to confirm proper
operation and reliability.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merit mpe33