Access to electrical
Turn off power to the fireplace by
either unplugging the power cord or
setting the circuit breaker in the
home's electrical panel to the "off"
position.
Remove screws in junction box
cover.
Wire connections to a) factory supplied
power cord or b) Romex power
supply should be as follows:
120VAC line fireplace
black
white
junction box
black
blue N1
blue N2
white
green green/yellow
For 240 VAC wiring see page 42