Lennox MPDT33RNM Care And Operation Instructions Manual

Merit plus series mpd direct-vent gas fireplaces

Advertisement

P/N 506017-06 Rev. A 08/2012
This manual is one of a set of two supporting this product.
Refer to P/N 506015-07 for Installation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 506223-44.
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . . . . 5
L'information de sûreté importante . . . . . . . . . . . . . . . 3–4
[EN FRANÇAIS]
Apposition des mises en garde relatives à la sécurité d'utilisation . . . . 5
Información importante de seguridad . . . . . . . . . . . . . . 3–4
[EN ESPAÑOL]
Colocación de advertencias de seguridad en operación . . . . . . . . . . . . 5
Wait...
INSTALLER: Leave this manual with the appliance.
DON'T
THROW
CONSUMER: Retain this manual for future reference.
IT AWAY!
This manual contains
INSTALLATEUR : Laissez cette notice avec l'appareil.
important operating
and safety
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
information.
WARNING / AVERTISSEMENT / AVISO
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
vapors and liquids in the vicinity of this or any other
appliance.
ry to light any appliance.
phone in your building.
neighbor'
instructions.
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
CARE AND OPERATION INSTRUC TIONS
MPD Direct-Vent
Gas Fireplaces
MODELS
MPDT33RNM
MPDT33RPM
MPDR33RNM
MPDR33RPM
MPD35CNM
MPD35RNM
OTL Report No. 116-F-13g-5
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
téléphones se trouvant dans le bâtiment où vous trouvez.
's
un voisin. Suivez les instructions du fournisseur.
appelez le service des incindies.
- 'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
MILLIVOLT:
MPD35RPM
MPDT33RNE
MPD40CNM
MPDR33RNE
MPD40RNM
MPD35CNE
MPD40RPM
MPD35RNE
MPD45RNM
MPD45RPM
Portland
US
r. Ne pas vous servir des
ELECTRONIC:
MPD40CNE
MPD40RNE
MPD45RNE

Advertisement

Table of Contents
loading

Summary of Contents for Lennox MPDT33RNM

  • Page 1 P/N 506017-06 Rev. A 08/2012 MODELS This manual is one of a set of two supporting this product. MILLIVOLT: ELECTRONIC: Refer to P/N 506015-07 for Installation Instructions. MPDT33RNM MPD35RPM MPDT33RNE MPD40CNE Ce manuel est disponible en francais, simplement MPDT33RPM MPD40CNM...
  • Page 2: Table Of Contents

    ® LENNOX HEARTH PRODUCTS • MERIT PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS Thank you for your purchase. We appreciate your business! Safety and Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 3 ® LENNOX HEARTH PRODUCTS • MERIT PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS [FRENCH] [SPANISH] La sécurité et Seguridad y votre foyer su chimenea Toutes les parties de votre foyer ¡Todas las partes de la chimenea...
  • Page 4: Important Safety Information

    ® LENNOX HEARTH PRODUCTS • MERIT PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS Important Safety Information L’information de sûreté importante 1. WARNING: Do not operate appliance with the glass front 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué...
  • Page 5: Attaching Safety-In-Operation Warnings

    3. If you are unable to locate the labels, please call (Figure C). Choisissez la langue qui est principale- Lennox Hearth Products o al distribuidor de Lennox Lennox Hearth Products or your nearest Lennox ment parlée dans la résidence du propriétaire.
  • Page 6: Appliance Installation, Service, And Maintenance Notices

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS APPLIANCE INSTALLATION, SERVICE, Young children should be carefully WARRANTY INFORMATION AND MAINTENANCE NOTICES supervised when they are in the same Your gas appliance is covered by a limited area as a hot termination.
  • Page 7: Btu Input

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS GENERAL INFORMATION Deration—At higher elevations, the amount Test gauge connections are provided on (continued) of BTU fuel value delivered must be reduced the front of the millivolt and electronic gas...
  • Page 8: Operation And Care Of Your Appliance

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS OPERATION AND CARE OF YOUR APPLIANCE Gas Controls/Control Compartment Access WARNING Operation of millivolt and electronic gas control systems is different. Before lighting...
  • Page 9: Variable Flame Height Adjustment

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS Variable Flame Height Adjustment Main Gas All Millivolt and electronic appliances are Control Knob equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fi...
  • Page 10: Maintenance

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS MAINTENANCE Cleaning Glass Replacing Logs (See Maintenance Schedule, Page 25 ) (see Front Glass Enclosure Panel, Removal If the logs become damaged by accident or and Installation on Page 11).
  • Page 11: Front Glass Enclosure Panel, Removal And Installation

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS Front Glass Enclosure Panel, Removal Locate the two (2) latches at the top of the WARNING control compartment and disengage them and Installation from the door frame bottom vee-fl...
  • Page 12: Install Volcanic Stone, Glowing Embers, And Logs

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS INSTALL VOLCANIC STONE, GLOWING Glowing Embers EMBERS, AND LOGS NOTE: Turn off all electricity to the appliance before you install volcanic stone, embers and logs.
  • Page 13 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS MPD33 LOG PLACEMENT Number Description (Stamped #) Log, Rear (39-12) Log, Left (39-1) Log, Right (39-2) Log, Top Center (39-13) Log, Top/Left (39-3 )
  • Page 14 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS MPD35 LOG PLACEMENT Number Description (Stamped #) Log, Rear (39-5) Log, Left (39-1) Log, Right (39-2) Log, Top Center (39-6) Log, Top/Left (39-3)
  • Page 15 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS MPD40 AND MPD45 LOG PLACEMENT Number Description (Stamped #) Log, Center (39-8) Log, Rear (138) Log, Right (39-10) Log, Left (39-9) Log, Top/Left (39-11)
  • Page 16: Burner Flame Appearance And Sooting

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper fl ame appearance is a fl ame which is blue at the base and becomes yellowish- orange in the body of the fl...
  • Page 17: Burner Flame Adjustments

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS BURNER FLAME ADJUSTMENTS Millivolt Appliance Checkout WARNING To light the burner, rotate the gas valve 1. Refer to Figures 10, 11, and 12 for control knob counterclockwise to the ON •...
  • Page 18: Wiring Diagrams

    Lennox Hearth Products distributor Please call Lennox Hearth Products for or dealer. the phone number of your nearest Lennox Parts will be shipped at prevailing prices at Hearth Products dealer who will answer your time of order.
  • Page 19: Accessory Components

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS ACCESSORY COMPONENTS Standard Remote Control System Deluxe Remote Control System The Model RCL (Standard) Remote Control The Model RCL-T (Deluxe) Remote Control System features a simple ON/OFF control...
  • Page 20 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS ACCESSORY COMPONENTS (continued) Termination Shroud (Fits H1968) Deluxe Termination Guard (Fits 94L10) s t i s t i Black Louvers MPD33 H8839 MPD33...
  • Page 21 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS ACCESSORY COMPONENTS (continued) Style View Doors Style View doors come in three styles. They are easy to install onto the standard glass door frame. Includes heavy-duty magnetic door latches and functional twin-pane doors.
  • Page 22 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS ACCESSORY COMPONENTS (continued) Grille Kits The distinctive sunrise design grille is available in black or satin pewter fi nish. This grille may be used to replace the standard radiant panels or optional louvered panels.
  • Page 23: Maintenance Schedule

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS MAINTENANCE SCHEDULE Annually (Before the onset of the Burning Season) Maintenance Task Accomplishing Person Procedure Inspect valve and ensure it is properly Inspect and Clean Burner, Logs Qualifi...
  • Page 24: Lighting Instructions - Millivolt

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life.
  • Page 25 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 26: Lighting Instructions-Electronic

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS LIGHTING INSTRUCTIONS—ELECTRONIC FOR YOUR SAFETY, READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life.
  • Page 27 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS INSTRUCTIONS D’ALLUMAGE—ELECTRONIC POUR PLUS DE SÉCURITÉ, LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 28: Troubleshooting Guide: Millivolt Gas Control System

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS TROUBLESHOOTING GUIDE: MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, make sure the external gas shut off valve (located at gas supply inlet) is in the “ON”...
  • Page 29: Troubleshooting Guide: Electronic Gas Control System

    LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS TROUBLESHOOTING GUIDE: ELECTRONIC GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, make sure the external gas shut off valve (located at gas supply inlet) is in the “ON”...
  • Page 30: Replacement Parts List

    * Lennox Nameplate Logo, 12L15, is not included. Gas Controls—SIT Millivolt Natural Gas Propane Gas Item Description Contact a Lennox Hearth Products dealer to obtain any of these Part No. Qty. Part No. Qty. parts. Never use substitute materials. Use of non-approved parts...
  • Page 31 LENNOX HEARTH PRODUCTS • MERIT PLUS ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS REPLACEMENT PARTS 40/45 33/35 40/45 33/35 40/45 33/35 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 32 ® DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • CARE AND OPERATION INSTRUCTIONS Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information.

Table of Contents