Control board
•
Replacement part # H1625
–
Contains:
–
Control Board
–
Remote Receiver
Procedure for replacing control board:
•
Disconnect Power Supply by
unplugging power cord or
turning off circuit breaker.
•
Orient replacement board to match
defective board.
•
Hold replacement board directly
below defective board.
•
Remove one wire at a time from
the defective board and connect it
to the replacement board.
•
Repeat until all wires have been
transferred.
•
Use needle nose pliers to squeeze
the plastic corner fasteners to
release the defective board.
Remove defective board
•
Place replacement board over
corner fasteners and push to lock
in place.
•
Confirm all connections with the
wiring diagram.
•
Restore power and test fireplace