Lights: Flame and Ember
•
With the flame cylinder
cover removed, the two
bulbs are visible.
•
When the flame switch is
activated the bulbs
should light and the
flame wheel should turn.
•
Use the remote control to
brighten and to dim the
flame bulbs and the
ember bed bulbs.
•
When testing voltage to
the ember and flame
lights:
– If the lights are
activated by the control
panel switch voltage
will be approximately
114VAC
– If the lights are
activated by the remote
control the dimmer
function will vary the
voltage from
approximately 4 VAC
(low) to 114 VAC at the
high setting.