FT-50 Fill Level Inspector Operation Guide
Diagnostic Error Descriptions
4-4
Error Number 2
An attempt was made to activate the rejector while the rejector status
function is turned off. For more information see "Chapter 3: Using the
System Software."
Error Number 5
The maximum limit of 32 containers between the trigger beam and the
rejector has been exceeded. Report this error to your Service Department.
Error Number 6
A consecutive reject timing error that occurs when an encoder pulse is
missed. One pulse per container is required, and starting and stopping the
conveyor suddenly while a container is in the inspection trigger zone, or
improper encoder calibration caused a missed pulse. Report this error to
your Service Department.
Error Number 10
This error occurs when the number of consecutively rejected containers
exceeds the limit set in the consecutive fill level reject alarm function.
Report this error to your Service Department.
Error Number 11
This error occurs when the number of consecutively rejected containers
exceeds the limit set in the consecutive missing cap reject alarm function.
Report this error to your Service Department.
Error Number 12
This error occurs when the number of consecutively rejected containers
exceeds the limit set in the consecutive high cap reject alarm function.
Report this error to your Service Department.
Error Number 13
This error indicates the gamma counts reaching the detector are 12%
below the of the reject threshold level. Report this error to your Service
Department.