Technical Data; Functional Data; Device Version; Explosion Protection - Siemens SIWAREX JB Instruction Manual

Aluminum housing
Table of Contents

Advertisement

4 Technical Data

4.1 Functional Data

Environmental temperature:
Storage temperature:
Protection:
Freedom of vibration of the terminals:
Insulation resistance of the terminals:

4.2 Device Version

Housing dimensions (LxWxH):
Housing material:
Weight:
Color:
Electrical connection:
Screw cable glands:

4.3 Explosion Protection

The junction box is simple electrical equipment in accordance with EN 60079-14
or EN 50020. It may be used in hazardous areas also for connecting intrinsically
safe circuits.
The terminals meet the requirement for separating intrinsically safe circuits – creep
and air gap > 6 mm.
WARNING
To be observed when using in hazardous areas:
The regulations governing the installation and operation of devices in
-
explosive areas that are in force in the country of use.
In EU countries, the laws passed in the relevant country to enforce EU
-
Directive 1999/92/EC
The regulations for erecting electrical installations in areas with a risk of
-
explosion DIN EN 60079-14 (VDE0165) or DIN EN1127-1.
EC Type Examination Certificate
-
All work on electrical circuits for systems where there is a risk of explosion must
be performed by qualified personnel.
SIWAREX JB junction box in aluminum housing – Instruction Manual
A5E00400544B
Load cells:
Signal cable:
-30 °C to +85 °C
-40 °C to +90 °C
IP 66, DIN 60529
Conforming with DIN VDE 0611 11/77:
12 Hz and 50 Hz, Amplitude 1 mm
12
10
Ohm cm
3
220 x 120 x 81 mm
aluminum AlSi12
approx. 2 kg
anthracite, Siemens color 614
Spring terminal connection 1.5/1 mm
4x M16 x 1.5
5 to 10 mm
2x M20 x 1.5
7 to 12 mm
2
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents